Results 51 to 60 of about 2,880 (232)

The effect of degassing on morphology and space charge

open access: yes, 2004
It is believed that space charge buildup in cross-linked polyethylene (XLPE) insulation is the main cause for premature failure of underground power cables. The space charge activities in XLPE depend on many factors such as additives, material treatment,
Chen, G, Chong, Y L, Ho, Y F F
core   +1 more source

Electric field requirements for charge packet generation and movement in XLPE [PDF]

open access: yes, 2001
The formation of space charge packets in XLPE (Cross-linked polyethylene) tapes from unaged cable insulation has been studied utilising the pulsed electro-acoustic (PEA) technique.
Dissado, L. A.   +2 more
core   +1 more source

Evaluation of Moisture Ageing Status of Cross‐Linked Polyethylene Insulation in Power Cables at Different Temperatures

open access: yesHigh Voltage, Volume 11, Issue 2, Page 410-420, April 2026.
ABSTRACT Cross‐linked polyethylene (XLPE) cables play an important role in power systems to transport electrical energy, and moisture is one of the important predisposing factors for insulation failure in medium and high‐voltage cables. In this paper, a temperature‐moisture accelerated ageing experiment is designed, and a method for assessing the ...
Wen Luo   +7 more
wiley   +1 more source

Significantly enhanced DC breakdown strength and high‐temperature resistivity of cross‐linked polyethylene through alloying polystyrene strategy

open access: yesHigh Voltage
Developing a stable insulation material stands as a crucial challenge for high‐voltage direct current (HVDC) cable insulation. This work proposes an alloying strategy to significantly enhance the breakdown strength and high‐temperature resistivity of ...
Muneeb Ahmed   +6 more
doaj   +1 more source

Time‐Domain Computation of Propagation Characteristics of Partial Discharge in Cross‐Linked Polyethylene High‐Voltage Cable Incorporating Modified Frequency‐Dependent Parameters

open access: yesHigh Voltage, Volume 11, Issue 2, Page 421-433, April 2026.
ABSTRACT The propagation characteristics of partial discharge (PD) in cables impact PD detection sensitivity, defect localisation accuracy and defect severity evaluation. Currently, the effects of semiconducting materials' frequency‐dependent properties and corrugated aluminium sheath structures on PD signal propagation in high‐voltage (HV) cables ...
Weisheng He   +6 more
wiley   +1 more source

Experimental investigation of E-beam effect on the electric field distribution in cross-linked polyethylene/ZnO nanocomposites for medium-voltage cables simulated by COMSOL Multiphysics

open access: yesJournal of Analytical Science and Technology, 2022
This study investigated the electric field distribution of underground cable insulation in cross-linked polyethylene/zinc oxide (XLPE/ ZnO) nanoparticles (NPs) for medium-voltage (MV) cables. The ZnO NPs that were obtained by three methods of preparation
A. I. Sharshir   +5 more
doaj   +1 more source

Effects of Exposure to Radiation and Steam on Silicone Rubber Cables Removed From a Nuclear Power Plant

open access: yesHigh Voltage, Volume 11, Issue 2, Page 482-493, April 2026.
ABSTRACT Low‐voltage cables insulated with silicone rubber were harvested from three locations in the primary containment vessel of a boiling water nuclear power plant (NPP). Subsequently, the cable, which was placed in an ambient environment with a relatively higher temperature and the highest rate, was cut into four shorter ones.
Yoshimichi Ohki   +2 more
wiley   +1 more source

Research on the discharge characteristics of XLPE insulated DC cables

open access: yesAIP Advances, 2021
This paper focuses on the discharge of cross-linked polyethylene (XLPE) insulated DC cables, which has become a concern of power utilities when carrying out a voltage withstand test or an outage maintenance.
Ying Liu, Xinlong Zheng
doaj   +1 more source

Space Charge Accumulation under Effects of Temperature Gradient and Applied Voltage Reversal on Solid Dielectric DC Cable [PDF]

open access: yes, 2009
A well-known fact of the existence and accumulation of space charge within the insulating material poses threat to the reliability in the operation of dc power cables.
Chen, George   +2 more
core   +1 more source

Investigation of the Impact of XLPE Cable Ageing on Impedance Mismatch Characteristics and Unbalanced Behaviour in Hybrid Operation Systems

open access: yesHigh Voltage, Volume 11, Issue 2, Page 544-555, April 2026.
ABSTRACT In the Hainan–Guangdong interconnection project, oil leakage in oil‐filled cables required replacing the faulty core with a single core from a three‐core cross‐linked polyethylene (XLPE) cable, leading to mixed operation of XLPE and oil‐filled cables.
Liang Zou   +4 more
wiley   +1 more source

Home - About - Disclaimer - Privacy