Results 51 to 60 of about 5,527,883 (197)

Space Charge Measurement and Modelling in Cross-Linked Polyethylene

open access: yesEnergies, 2020
Cross-linked polyethylene, commercially known as XLPE, is widely used as an insulating material in high voltage cables. However, space charge accumulation under the DC field is one of the most challenging problems in the further development of XLPE ...
Yunpeng Zhan   +6 more
doaj   +1 more source

Evaluation of Moisture Ageing Status of Cross‐Linked Polyethylene Insulation in Power Cables at Different Temperatures

open access: yesHigh Voltage, Volume 11, Issue 2, Page 410-420, April 2026.
ABSTRACT Cross‐linked polyethylene (XLPE) cables play an important role in power systems to transport electrical energy, and moisture is one of the important predisposing factors for insulation failure in medium and high‐voltage cables. In this paper, a temperature‐moisture accelerated ageing experiment is designed, and a method for assessing the ...
Wen Luo   +7 more
wiley   +1 more source

The Extra‐Low Frequency Dielectric Analysis Method for Evaluating Byproducts of Cross‐Linked Polyethylene Cable Insulation Materials

open access: yesHigh Voltage
Cross‐linking byproducts in the cross‐linked polyethylene (XLPE) cable insulation material significantly affect the insulation properties of XLPE, and the non‐destructive detection method for cross‐linking byproducts during cable degassing process still ...
Wenpeng Li   +8 more
doaj   +1 more source

Time‐Domain Computation of Propagation Characteristics of Partial Discharge in Cross‐Linked Polyethylene High‐Voltage Cable Incorporating Modified Frequency‐Dependent Parameters

open access: yesHigh Voltage, Volume 11, Issue 2, Page 421-433, April 2026.
ABSTRACT The propagation characteristics of partial discharge (PD) in cables impact PD detection sensitivity, defect localisation accuracy and defect severity evaluation. Currently, the effects of semiconducting materials' frequency‐dependent properties and corrugated aluminium sheath structures on PD signal propagation in high‐voltage (HV) cables ...
Weisheng He   +6 more
wiley   +1 more source

CTA-mediated free radical cross-linking behavior toward highly cross-linked polyethylene with enhanced dielectric performance

open access: yesAPL Materials
Developing highly cross-linked low-density polyethylene to improve dielectric performance is the key to ensuring the reliability and stability of high-voltage cables.
Kai Shang   +5 more
doaj   +1 more source

Effects of Exposure to Radiation and Steam on Silicone Rubber Cables Removed From a Nuclear Power Plant

open access: yesHigh Voltage, Volume 11, Issue 2, Page 482-493, April 2026.
ABSTRACT Low‐voltage cables insulated with silicone rubber were harvested from three locations in the primary containment vessel of a boiling water nuclear power plant (NPP). Subsequently, the cable, which was placed in an ambient environment with a relatively higher temperature and the highest rate, was cut into four shorter ones.
Yoshimichi Ohki   +2 more
wiley   +1 more source

Propagation Mechanism of Electrical Tree in XLPE Cable Insulation by investigating a Double Electrical Tree Structure

open access: yes, 2008
This paper presents our experiments and analysis of the electrical tree growing characteristics. The relationship between electrical tree propagation and the material morphology in XLPE cable insulation has been studied by researching the structure and ...
Zheng, Xiaoquan, Chen, George
core   +1 more source

Influence of Combined Electrothermal Aging on Dielectric and Thermal Properties of HVAC XLPE Cable

open access: yesEnergies, 2023
To explore the influence of electrothermal aging on the properties of HVAC XLPE cable during its normal operation, two circuits of 110 kV XLPE cable were subjected to a combined electrothermal accelerated aging test for 180 days. The test voltage was set
Zhihui Xu   +4 more
doaj   +1 more source

Thermal Effect of Short-term Overload on High-voltage Cross-linked Polyethylene (XLPE) Cable Insulation

open access: yesIOP Conference Series: Materials Science and Engineering, 2020
Abstract This paper describes changes on micro-structure and aggregation structure of cross-linked polyethylene (XLPE) with different thermal histories after different times of overheating treatment to analogize the short-term fault or emergency overload in actual operating cables.
Wenwei Zhu   +5 more
openaire   +1 more source

Investigation of the Impact of XLPE Cable Ageing on Impedance Mismatch Characteristics and Unbalanced Behaviour in Hybrid Operation Systems

open access: yesHigh Voltage, Volume 11, Issue 2, Page 544-555, April 2026.
ABSTRACT In the Hainan–Guangdong interconnection project, oil leakage in oil‐filled cables required replacing the faulty core with a single core from a three‐core cross‐linked polyethylene (XLPE) cable, leading to mixed operation of XLPE and oil‐filled cables.
Liang Zou   +4 more
wiley   +1 more source

Home - About - Disclaimer - Privacy