Results 41 to 50 of about 1,315 (207)

Wave‐Velocity‐Based Temperature Monitoring Applied to Underground Power Cables in Medium‐Voltage Networks—Discrimination of Individual Cable Temperatures in a Distribution Grid

open access: yesHigh Voltage, EarlyView.
ABSTRACT The thermal state of underground power cables can be monitored based on the temperature dependency of the dielectric permittivity of the insulation material. The resulting temperature‐dependent wave velocity is used as a thermometric property. To this end, the signal propagation time along a cable of an injected signal is determined.
Peter Wouters   +2 more
wiley   +1 more source

Melt Grafting of Geometry‐Tailored Voltage Stabilizers for High‐Performance Polypropylene Insulation

open access: yesAdvanced Functional Materials, Volume 36, Issue 30, 13 April 2026.
A scalable one‐step melt grafting strategy is developed to enhance the dielectric properties of isotactic polypropylene by covalently incorporating thermally stable aromatic voltage stabilizers. This solvent‐free approach improves volume resistivity and DC breakdown strength through deep trap formation and charge localization, offering a sustainable ...
Nazirul Mubin bin Normansah   +9 more
wiley   +1 more source

Space Charge Formation and its Modified Electric Field under Applied Voltage Reversal and Temperature Gradient in XLPE Cable

open access: yes, 2008
The results of space charge evolution in cross-linked polyethylene power cables under dc electrical field at a uniform temperature and during external voltage polarity reversal are presented in the paper.
Fu, Mingli   +11 more
core   +1 more source

Experimental investigation of E-beam effect on the electric field distribution in cross-linked polyethylene/ZnO nanocomposites for medium-voltage cables simulated by COMSOL Multiphysics

open access: yesJournal of Analytical Science and Technology, 2022
This study investigated the electric field distribution of underground cable insulation in cross-linked polyethylene/zinc oxide (XLPE/ ZnO) nanoparticles (NPs) for medium-voltage (MV) cables. The ZnO NPs that were obtained by three methods of preparation
A. I. Sharshir   +5 more
doaj   +1 more source

Evaluation of Moisture Ageing Status of Cross‐Linked Polyethylene Insulation in Power Cables at Different Temperatures

open access: yesHigh Voltage, Volume 11, Issue 2, Page 410-420, April 2026.
ABSTRACT Cross‐linked polyethylene (XLPE) cables play an important role in power systems to transport electrical energy, and moisture is one of the important predisposing factors for insulation failure in medium and high‐voltage cables. In this paper, a temperature‐moisture accelerated ageing experiment is designed, and a method for assessing the ...
Wen Luo   +7 more
wiley   +1 more source

Research on the discharge characteristics of XLPE insulated DC cables

open access: yesAIP Advances, 2021
This paper focuses on the discharge of cross-linked polyethylene (XLPE) insulated DC cables, which has become a concern of power utilities when carrying out a voltage withstand test or an outage maintenance.
Ying Liu, Xinlong Zheng
doaj   +1 more source

Time‐Domain Computation of Propagation Characteristics of Partial Discharge in Cross‐Linked Polyethylene High‐Voltage Cable Incorporating Modified Frequency‐Dependent Parameters

open access: yesHigh Voltage, Volume 11, Issue 2, Page 421-433, April 2026.
ABSTRACT The propagation characteristics of partial discharge (PD) in cables impact PD detection sensitivity, defect localisation accuracy and defect severity evaluation. Currently, the effects of semiconducting materials' frequency‐dependent properties and corrugated aluminium sheath structures on PD signal propagation in high‐voltage (HV) cables ...
Weisheng He   +6 more
wiley   +1 more source

Charge transport mechanism of cross‐linked polyethylene/silicone rubber composite insulation by energy band theory

open access: yesHigh Voltage, 2023
The composite insulation composed of cross‐linked polyethylene (XLPE) and silicone rubber (SiR) is common in high voltage direct current cable accessory installation.
Yani Wang   +4 more
doaj   +1 more source

Effects of Exposure to Radiation and Steam on Silicone Rubber Cables Removed From a Nuclear Power Plant

open access: yesHigh Voltage, Volume 11, Issue 2, Page 482-493, April 2026.
ABSTRACT Low‐voltage cables insulated with silicone rubber were harvested from three locations in the primary containment vessel of a boiling water nuclear power plant (NPP). Subsequently, the cable, which was placed in an ambient environment with a relatively higher temperature and the highest rate, was cut into four shorter ones.
Yoshimichi Ohki   +2 more
wiley   +1 more source

Space charge dynamics in oil and thick pressboard combined system under polarity reversal voltage [PDF]

open access: yes, 2014
In this study, the space charge dynamics in an oil and oil impregnated pressboard combined insulation system are investigated by the means of pulsed electroacoustic (PEA) technique under voltage polarity reversal conditions. To be closer to the real case
Hao, Miao   +9 more
core   +1 more source

Home - About - Disclaimer - Privacy