Results 201 to 210 of about 1,375,104 (247)
Some of the next articles are maybe not open access.

Optical current sensors eliminate CT saturation

2002 IEEE Power Engineering Society Winter Meeting. Conference Proceedings (Cat. No.02CH37309), 2003
Optical current sensors are achieving increased acceptance and use in high voltage substations due to their superior accuracy, bandwidth, dynamic range and inherent isolation. Once deemed specialized devices intended for novel applications, optical sensors have risen to a performance level exceeding conventional magnetic devices.
openaire   +1 more source

New Method to Identify CT Saturation Based on EMD

Advanced Materials Research, 2013
Aiming at the problem that Current Transformer (CT) affects differential protection, this paper proposes a new method to identify CT saturation based on Empirical Mode Decomposition (EMD). Differential current can be decomposed into few Intrinsic Mode Functions (IMFs) by EMD.
Wen Hua Xia   +4 more
openaire   +1 more source

Phasor Estimation in the Presence of DC Offset and CT Saturation

IEEE Transactions on Power Delivery, 2009
A hybrid algorithm for phasor estimation is proposed that is immune to DC offset and current transformer (CT) saturation problems. The algorithm utilizes partial sum (PS)-based and multistage least-squares (MLS)-based methods before and after CT saturation is detected, respectively.
Soon-Ryul Nam   +3 more
openaire   +1 more source

Beyond the knee point: A practical guide to CT saturation

2018 71st Annual Conference for Protective Relay Engineers (CPRE), 2018
Current transformer (CT) saturation, while a fairly common occurrence in protection systems, is not often clearly understood by protective relay engineers. This paper forgoes the usual physics equations to describe how CTs saturate in a simple and intuitive way.
Ariana Hargrave   +2 more
openaire   +1 more source

Phasor measurement and CT saturation compensation through embedding

2013 IEEE Power & Energy Society General Meeting, 2013
Phasor measurement measures the amplitude and phase angle of the signal to determine the health of the power system. If a fault occurs on a transmission line, the input current of a relay may contain harmonics and exponentially decaying DC offset. This paper proposes an embedding-based scheme, which transfers a power system signal to the phase space ...
T. Y. Ji, M. S. Li, Q. H. Wu
openaire   +1 more source

An adaptive differential relay for CT saturation based on wavelet Transform

IEEE PES T&D 2010, 2010
Differential protection relays may false tripping for external faults due to current transformer saturation (CT). This paper presents an adaptive technique for transformer differential protection against saturation of current transformers, based on differential currents. A Wavelet Index (WI) by wavelet Transform has been devised using extracted feature
openaire   +1 more source

A busbar protection technique and its performance during CT saturation and CT ratio-mismatch

IEEE Transactions on Power Delivery, 2000
This paper describes a digital technique for protecting busbars. The technique uses positive- and negative-sequence models of the power system in a fault-detection algorithm. While phase voltages and currents are used to detect faults, parameters of the power system are not used.
M.S. Sachdev, T.S. Sidhu, H.S. Gill
openaire   +1 more source

A new differential protection scheme for busbar considering CT saturation effect

2011 24th Canadian Conference on Electrical and Computer Engineering(CCECE), 2011
The protection of busbar demands high integrity and high speed relaying scheme. This paper presents a new differential relaying scheme for the protection of busbar. The proposed scheme depends on the difference of the value of incoming and outgoing line currents of the respective phase at a particular bus.
Nilesh Chothani, Bhavesh R. Bhalja
openaire   +2 more sources

A novel CT saturation identification scheme for differential protection of generators

2011 IEEE Power and Energy Society General Meeting, 2011
A new CT saturation block scheme for generator differential protection implemented with mathematical morphology filter is presented. By use of the excellent singularity detecting together with the noise-repressing abilities, the time difference between fault occurrence and differential current emergence instant can be extracted in real time with very ...
Xiangning Lin, Zhiqian Bo
openaire   +1 more source

Distance Element Performance Under Conditions of CT Saturation

2008 61st Annual Conference for Protective Relay Engineers, 2008
Distance elements are widely used on transmission, subtransmission, and even distribution systems. Distance-based schemes are also a very economical and simple approach to protecting these lines. The ease of use of distance elements, especially in modern digital relays, has expanded the application to shorter and shorter lines.
openaire   +1 more source

Home - About - Disclaimer - Privacy