Results 261 to 270 of about 64,705 (311)
Some of the next articles are maybe not open access.

Surge protectors for current transformers

Electrical Engineering, 1936
Surge protection and open-circuit protection of current transformers may be obtained by the application of shunts in which the material known as ``thyrite,'' and which has a negative resistance characteristic, is used. The surge protector is connected across the current transformer primary, and the open-circuit protector across the secondary.
G. Camilli, L. V. Bewley
openaire   +1 more source

On site calibration of current transformers

2014 IEEE International Instrumentation and Measurement Technology Conference (I2MTC) Proceedings, 2014
This paper proposes a method for calibrating current transformers installed in power networks. The method compares primary to secondary currents in low voltage networks, and different secondary currents of the same transformer in high voltage networks.
Leonardo Trigo   +3 more
openaire   +1 more source

Current transformers

American Journal of Physics, 1986
Current transformers are used primarily to measure time varying currents under conditions where some degree of isolation from the primary circuit is desired. In this paper, the basic physics of current transformers is considered and several useful techniques for extending their performance are described.
openaire   +1 more source

Current-mode network transformations

Proceedings of IEEE International Symposium on Circuits and Systems - ISCAS '94, 2002
Current-mode network transformations are presented from which it is possible to generate new current-mode circuits by performing simple operations on the network. These transformations are developed by interchanging the ports of a current-mode circuit and exploiting the properties of current-conveyors and RC networks.
Mehul Desai   +2 more
openaire   +1 more source

A Wideband Current Transformer Bridge

IEEE Transactions on Instrumentation and Measurement, 2014
The development and testing results of a new current transformer (CT) test set at Physikalisch-Technische Bundesanstalt are described. The operation range for the ratio based bridge is intended for frequencies from 16.7 Hz up to 20 kHz. Equal setups of magnetically shielded current comparators with primary windings for rated currents from 100 mA up to ...
Enrico Mohns   +3 more
openaire   +1 more source

Current summations with current transformers

Journal of the Institution of Electrical Engineers, 1955
The behaviour of current transformers in parallel, and of similar circuits employing summation transformers, is studied for different conditions of load distribution.After the existing theory concerning idle currents has been rejected it is demonstrated that the overall error is very nearly constant for a given total load, no matter how the current may
openaire   +1 more source

Transformer magnetizing inrush currents

Electrical Engineering, 1951
THERE ARE formulas available by which it is possible to calculate the peak of the first cycle of magnetizing inrush current for a transformer. There have been no convenient formulas available for determining the maximum values of successive cycles of current.
openaire   +1 more source

Methods for Testing Current Transformers

Transactions of the American Institute of Electrical Engineers, 1924
In the sale of electric power especially in large amounts at high voltages, current transformers are universally used to operate the meters from the readings of which the bills are made out. While the secondary currents of such transformers reproduce fairly faithifully on a smaller scale the conditions of current strength and phase existing in their ...
openaire   +1 more source

Compensation of nonlinearities in a current transformer for the reconstruction of the primary current

IEEE Transactions on Control Systems Technology, 2001
The measurement of the current in industrial electrical devices is often carried out by current transformers. The reliability of these devices is compromised when the measured current is higher than the nominal value, due to the saturation and hysteresis effects of the magnetic core.
BITTANTI, SERGIO   +3 more
openaire   +2 more sources

The Phase Angle of Current Transformers

Transactions of the American Institute of Electrical Engineers, 1915
A method of testing the phase angle of current transformers by comparing readings obtained on a wattmeter whose current circuit is first connected to receive a part of the primary current (the remainder of the primary current passing in shunt through resistance) and then connected to the secondary circuit; the potential circuit is supplied from the ...
openaire   +1 more source