Results 51 to 60 of about 41,086 (208)
The simulation of a twelve pulse diode rectifier with saturable reactors [PDF]
A twelve pulse diode rectifier with saturable reactors to allow a degree of phase control is simulated using mathematical software. First order differential equations are solved numerically to allow calculation of line current.
King, I.G, Moore, P.J.
core
Solid-State Transformers for Interfacing Solar Panels to the Power Grid: An Optimum Design Methodology of a High Frequency Transformer for dc-dc Converter Applications [PDF]
Nowadays the use of power electronic interfaces to integrate distributed generation with the power grid is becoming relevant due to the increased penetration of renewable energy sources like solar, and the continued ...
George, Kenny
core +2 more sources
Performance Problems of Non-Toroidal Shaped Current Transformers
Nowadays, non-toroidal shape primary pass-through current transformers are commonly used for large current machines with several cables per phase. As these transformers exhibit no radial symmetry, it is not clear if they can be tested using the indirect ...
Carlos A. Platero +4 more
doaj +1 more source
Base drive for paralleled inverter systems [PDF]
In a paralleled inverter system, a positive feedback current derived from the total current from all of the modules of the inverter system is applied to the base drive of each of the power transistors of all modules, thereby to provide all modules ...
Nagano, S.
core +1 more source
Apparatus for measuring current flow Patent [PDF]
Electric current measuring apparatus design including saturable core transformer and energy storage device to avoid magnetizing current errors from transformer output ...
Paulkovich, J.
core +1 more source
Frequency response analysis is widely used for the offline diagnosis of winding deformations in power transformers. To apply this approach to a working transformer, the magnitude of the response current needs to be measured by using Rogowski coil sensors
Yangchun Cheng +4 more
doaj +1 more source
The dependability and security of transformer differential protection can be compromised by current transformer (CT) saturation, which distorts current measurements and may lead to the maloperation of protective relays.
Sopheap Key +4 more
doaj +1 more source
CORRECTION OF THE HIGH-FREQUENCY TRANSFORMER ASYMMETRY OF UNDISTURBED POWER SUPPLY OF LIMITED POWER [PDF]
Study the possibilities to adjust asymmetry of the high frequency transformer as a component of an undisturbed power supply ...
BORODAI, Valery +13 more
core
Smart Sensor System Application: An Integrated Compass [PDF]
A fully integrable electronic compass has been designed based on the pulse position method, using micro-machined fluxgate magnetic sensors. The compass has been designed to have an accuracy of one degree.
Diemel, Guido +2 more
core +6 more sources
Current transformer saturation detection by cross-correlation with independent target signal
The saturation of current transformers (CTs) leads to distortion in secondary current, potentially causing malfunction in protective relays within power systems.
Mahmoud M. Elgamasy +3 more
doaj +1 more source