Results 251 to 260 of about 1,889,331 (297)
Some of the next articles are maybe not open access.

Vector active filter without current hysteresis controllers

ISIE'2000. Proceedings of the 2000 IEEE International Symposium on Industrial Electronics (Cat. No.00TH8543), 2002
This paper presents the theoretical fundamentals and the digital simulation of a three-phase power active filter, whose control strategy is strictly vector-based. This vector control strategy determines first the region, within the inverter voltage vector hexagon, where the compensation current deviation instantaneous space vector /spl Delta/i/sub c ...
A.E. Nava-Segura   +2 more
openaire   +1 more source

Current vector control challenges in the fight against malaria

Acta Tropica, 2017
The effective and eco-friendly control of Anopheles vectors plays a key role in any malaria management program. Integrated Vector Management (IVM) suggests making use of the full range of vector control tools available. The strategies for IVM require novel technologies to control outdoor transmission of malaria.
Benelli, Giovanni, Beier, John C
openaire   +3 more sources

Universal current vector controller for vector-controlled induction motors based on control of motional electromotive force

2005 International Conference on Electrical Machines and Systems, 2005
A universal current vector controller for vector-controlled induction motor (IM) drives, based on control of motional electromotive force (MEMF), is presented. It is demonstrated that the rotor field orientation decouples not only flux and torque but also transformer electromotive force (TEMF) and MEMF in rotor.
null Ming Meng   +2 more
openaire   +1 more source

Active filter controlled by differentiation of current vector

Proceedings of the Power Conversion Conference-Osaka 2002 (Cat. No.02TH8579), 2003
In this paper, a new control technique is proposed for the active filter using the current source converter. The control circuit of the proposed system is very simple, because the references of compensation currents aren't necessary. The compensation of line current with a filter circuit can be automatically obtained by PWM control based on the ...
Y. Minamoto, T. Ohnishi
openaire   +1 more source

An Integrated Vector Control Strategy for BLDC Current

2019 IEEE 3rd Information Technology, Networking, Electronic and Automation Control Conference (ITNEC), 2019
To improve the flux-weakening capability of a brushless DC motor (BLDC) with trapezoidal wave, here is a 120° conduction square wave control stratgey. In this paper, a novel current integrated vector control strategy is proposed based on stator current prime vector.
Peng Luo   +5 more
openaire   +1 more source

A Review on Vector Borne Disease Transmission: Current Strategies of Mosquito Vector Control

Indian Journal of Entomology, 2022
.In this review, the mosquito vector borne diseases (VBD) majorly malaria, dengue, filariasis, chikungunya, Japanese encephalitis, Zika were presented to comprehend the global disease incidence as the control of these disease transmitting vectors are challengeable globally nowadays.
S Manikandan   +5 more
openaire   +1 more source

An improved space-vector-based hysteresis current controller

IEEE Transactions on Industrial Electronics, 1998
In this paper, an improved space-vector-based hysteresis current controller (SVBHCC) is proposed. The controller determines a set of space vectors from a region detector and applies a space voltage vector selected according to the main HCC. A set of space vectors including the zero voltage vector to reduce the number of switchings is determined from ...
Kwon, BH, Min, BD, Youm, JH
openaire   +2 more sources

Inverter nonlinearities and discrete-time vector current control

IEEE Transactions on Industry Applications, 1994
The authors study all-digital discrete-time vector current control loops containing a voltage-fed inverter in series with a permanent magnet synchronous motor. Normal operation of the typical pulse width modulating voltage fed inverter introduces nonlinear distortion into the voltage and the current waveforms of the motor. The authors consider both the
R.B. Sepe, J.H. Lang
openaire   +1 more source

Current Controller for Autocommissioned Vector-Controlled Induction Motor Drives

Electric Machines & Power Systems, 2000
A current controller composed of a current regulator associated to a parameter adaptation scheme is proposed. The current regulator considers the inherent coupled structure of the induction machine. The adaptive block is coupled to this regulator in order to carry out a high performance current control with low sensitivity to parameter variations.
openaire   +1 more source

DFIM vector control sensitivity with current sensor faults

COMPEL - The international journal for computation and mathematics in electrical and electronic engineering, 2010
PurposeThe purpose of this paper is to present a doubly fed induction machine (DFIM) operating in motor mode and supplied by two voltage source inverters (in stator and rotor sides).Design/methodology/approachThe aim is to analyze the current sensor fault effects on the stator flux‐oriented control according to the current input‐output decoupling. This
Abdellatif, Meriem   +2 more
openaire   +2 more sources

Home - About - Disclaimer - Privacy