Results 61 to 70 of about 16,999 (226)

DC fault detection and location in meshed multi-terminal HVDC systems based on DC reactor voltage change rate [PDF]

open access: yes, 2017
The change rate of the DC reactor voltage with predefined protection voltage thresholds is proposed to provide fast and accurate DC fault detection in a meshed multi-terminal HVDC system.
Li, Rui, Xu, Lie, Yao, Liangzhong
core   +1 more source

Series LC DC circuit breaker

open access: yesHigh Voltage, 2019
The article proposes a mechanical DC circuit breaker (CB) based on a series LC circuit. It requires two switches (a fast disconnector and an AC circuit breaker), an inductor and a capacitor, and therefore the cost is expected to be low. A series LC circuit is analysed and it is concluded that fault current will always have natural zero‐current ...
openaire   +3 more sources

Investigation of the Simplified Equivalent Circuit Model of the Post‐Arc Sheath Stage in DC Vacuum Circuit Breakers

open access: yesHigh Voltage, EarlyView.
ABSTRACT This paper presents a simplified equivalent circuit model (ECM) for the post‐arc sheath stage in DC vacuum circuit breakers and outlines the method for calculating circuit parameters using the particle‐in‐cell Monte Carlo collision (PIC‐MCC) method. The post‐arc sheath is modelled as a parallel combination of a variable resistor and a variable
Xubin Li   +5 more
wiley   +1 more source

Modular multilevel converter with modified half-bridge submodule and arm filter for dc transmission systems with DC fault blocking capability [PDF]

open access: yes, 2018
Although a modular multilevel converter (MMC) is universally accepted as a suitable converter topology for the high voltage dc transmission systems, its dc fault ride performance requires substantial improvement in order to be used in critical ...
Abdelsalam, Ibrahim A.   +3 more
core   +2 more sources

Surface Micro‐Discharge Plasma for Multiple Teeth Bleaching: Efficacy, Mechanism and Safety

open access: yesHigh Voltage, EarlyView.
ABSTRACT Hydrogen peroxide (H2O2) is the commonly‐used bleaching chemical in clinical practice, but its excessive concentrations can cause tooth damage. Atmospheric pressure cold plasma is considered a promising new technique for tooth bleaching. Surface micro‐discharge (SMD) devices can generate large‐scale plasma, which holds potential for treating ...
Ruike Chen   +7 more
wiley   +1 more source

Short-Circuit Fault Current Modeling of a DC Light Rail System with a Wayside Energy Storage Device

open access: yesEnergies, 2022
This paper proposes a simulation model to calculate short-circuit fault currents in a DC light rail system with a wayside energy storage device. The simulation model was built in MATLAB/Simulink using the electrical information required to define a ...
Petru Valentin Radu   +3 more
doaj   +1 more source

Determination of protection system requirements for DC UAV electrical power networks for enhanced capability and survivability [PDF]

open access: yes, 2011
A growing number of designs of future Unmanned Aerial Vehicle (UAV) applications utilise dc for the primary power distribution method. Such systems typically employ large numbers of power electronic converters as interfaces for novel loads and generators.
Burt, Graeme   +3 more
core   +1 more source

Post‐Arc Transient Dielectric Recovery Characteristics of Vacuum Interrupter in the Large‐Capacity Generator Circuit Breaker

open access: yesHigh Voltage, EarlyView.
ABSTRACT Large‐capacity generator circuit breaker (GCB) based on vacuum interrupter technology is the key power equipment to ensure the safe operation of the power system. When the short‐circuit current was forced to cross zero, the large‐capacity GCB was difficult to generate a zero‐voltage environment through freewheeling, the vacuum interrupter (VI)
Xiangyu Han   +8 more
wiley   +1 more source

Arc Resistance Enhancement of Converter Transformer Tank Through Structural Improvements: Simulation and Experimental Validation

open access: yesHigh Voltage, EarlyView.
ABSTRACT Currently, limited research exists on the structural response and protection methods of the converter transformer tank for ± 800 kV ultra‐high voltage direct current transmission project to high energy arc faults. This research investigates the dynamic response and the vulnerable areas of the ultra‐high voltage converter transformer under the ...
Ke Wang   +5 more
wiley   +1 more source

Interruption characteristics of self-powered hybrid DC circuit breaker with synergistic effect of step-down and divided current

open access: yesInternational Journal of Electrical Power & Energy Systems
The DC voltage level of photovoltaic and PEDF applications have continuously advanced, reaching up to DC3000V. This presents new requirements for DC circuit breakers operating at higher voltages (>DC1500V) to ensure effective fault protection in the DC ...
Jianning Yin   +4 more
doaj   +1 more source

Home - About - Disclaimer - Privacy