Analysis of power system transient stability with PSO-optimized distributed generation and HVDC transmission systems. [PDF]
Jang J, Gong Y, Min S, Kim I.
europepmc +1 more source
Integrating digital twins with neural networks for adaptive control of automotive suspension systems. [PDF]
Qiu H +6 more
europepmc +1 more source
Robust algorithm development of frequency estimation in smart grid. [PDF]
Yu Y, Yang Y, Wang X, Lv L, Chen Y.
europepmc +1 more source
Optimal Control Method for Microgrid Distributed Generation Based on Multi-Agent Adaptive Decision-Making. [PDF]
Mai H, Teng Q, Wang X.
europepmc +1 more source
Adaptive fuzzy-PI controlled dynamic voltage restorer for mitigating voltage sags. [PDF]
Mallick N +5 more
europepmc +1 more source
Related searches:
A DC Solid-State Transformer With DC Fault Ride-Through Capability
IEEE Journal of Emerging and Selected Topics in Power Electronics, 2022This paper investigates a dc solid state transformer (DCSST) with dc fault ride-through (FRT) capability for medium voltage dc (MVDC) systems. The fault ride through requirement for DCSST in dc gird is investigated. Short circuit fault clearance on the medium voltage (MV) side is realized by introducing full bridge converters with cascaded dc converter
Haoyuan Weng +5 more
openaire +3 more sources
Fault Ride Through in DC Microgrid with Faster Recovery
IECON 2020 The 46th Annual Conference of the IEEE Industrial Electronics Society, 2020Breaking of fault current in dc microgrid has been a challenge due to lack of dc current zero crossing. The fault current in case of pole to pole fault is high and even higher in the presence of multiple generators as all the generators feed current to the fault. This results in very high current in the faulted line. Clearing such high fault current is
Kuppili Anirudh +2 more
openaire +1 more source
An enhanced MMC topology with DC fault ride-through capability
IECON 2013 - 39th Annual Conference of the IEEE Industrial Electronics Society, 2013High-voltage direct current system using modular multilevel converter (MMC-HVDC) is a potential candidate for grid integration of renewable energy over long distances. The dc-link fault is an issue MMC-HVDC must deal with. This paper proposed an enhanced MMC topology with dc fault ride-through capability.
Xiaoqian Li +4 more
openaire +1 more source
A fault ride through strategy of multi-ports DC transformer
2020 5th International Conference on Automation, Control and Robotics Engineering (CACRE), 2020DC transformer (DCT) is the main and key equipment of DC distribution network. Multi-ports DCT can connect multiple DC lines or networks at the same time, which has high power supply reliability and is suitable for interconnection equipment among different DC power grids.
openaire +1 more source