Results 71 to 80 of about 561,838 (264)
Aldehyde dehydrogenase 1A1 (ALDH1A1) is a cancer stem cell marker in several malignancies. We established a novel epithelial cell line from rectal adenocarcinoma with unique overexpression of this enzyme. Genetic attenuation of ALDH1A1 led to increased invasive capacity and metastatic potential, the inhibition of proliferation activity, and ultimately ...
Martina Poturnajova +25 more
wiley +1 more source
The article proposes a new method for measuring frequency based on a one-bit ADC. In contrast to the known method of measuring frequency using a delay line, the developed structure of a meter that implements the proposed method makes it possible to get ...
A. N. Lyashuk +2 more
doaj +1 more source
Attosecond stable dispersion-free delay line for easy ultrafast metrology. [PDF]
Tyagi A +7 more
europepmc +1 more source
Pre‐analytical handling critically determines liquid biopsy performance. This study defines practical best‐practice conditions for cell‐free DNA (cfDNA) and extracellular vesicle–derived DNA (evDNA), showing how processing time, storage conditions, tube type, and plasma input volume affect DNA integrity and mutation detection.
Jonas Dohmen +11 more
wiley +1 more source
Preparation of MoS2 Nanospheres using a Hydrothermal Method and Their Application as Ammonia Gas Sensors Based on Delay Line Surface Acoustic Wave Devices. [PDF]
Chung CY +4 more
europepmc +1 more source
Keratin 19 (KRT19) is overexpressed in high‐grade serous ovarian cancer with high levels of Kallikrein‐related peptidases (KLK) 4–7 and is associated with poor survival. In vivo analyses demonstrate that elevated KRT19 increases peritoneal tumour burden.
Sophia Bielesch +13 more
wiley +1 more source
Acoustic sensor for remote measuring of pressure [PDF]
The paper deals with sensors based on delay lines on surface acoustic waves (SAW), having a receiving-emitting and a reflective interdigital transducers (IDT).
Kataev V. F. +3 more
doaj
Angle of arrival (AOA) estimation for wideband signal becomes more necessary for modern communication systems like Global System for Mobile (GSM), satellite, military applications and spread spectrum (frequency hopping and direct sequence).
Bassim Sayed Mohammed +1 more
doaj +1 more source
Phase Noise of SAW Delay Line Magnetic Field Sensors. [PDF]
Durdaut P +8 more
europepmc +1 more source
We have established a humanized orthotopic patient‐derived xenograft (Hu‐oPDX) mouse model of high‐grade serous ovarian cancer (HGSOC) that recapitulates human tumor–immune interactions. Using combined anti‐PD‐L1/anti‐CD73 immunotherapy, we demonstrate the model's improved biological relevance and enhanced translational value for preclinical ...
Luka Tandaric +10 more
wiley +1 more source

