Results 61 to 70 of about 169 (164)

Evaluating feature extraction reproducibility across image biomarker standardization initiative‐compliant radiomics platforms using a digital phantom

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Background The aim of this study was to thoroughly analyze the reproducibility of radiomics feature extraction across three Image Biomarker Standardization Initiative (IBSI)‐compliant platforms using a digital phantom for benchmarking. It uncovers high consistency among common features while also pointing out the necessity for standardization ...
Han‐Back Shin   +5 more
wiley   +1 more source

AAPM Task Group No. 249.B—Essentials and guidelines for clinical medical physics residency training program

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract The establishment of guidelines and curriculum standards for medical physics residency training is a critical component of setting expectations and competencies for the profession. Since the last publication of these standards, residency training has become integrated into the eligibility criteria for most medical physics certification bodies.
Jonathon A. Nye   +16 more
wiley   +1 more source

Developing reference plans for evaluating global clinical trials credentialing and PSQA systems

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose To develop a practical framework for creating a diverse set of validated reference plans (varying in complexity) and implement a workflow to introduce beam modeling, calibration, and delivery errors into the reference cohort to test and compare various dosimetry audit methodologies.
Fre'Etta M. D. Brooks   +13 more
wiley   +1 more source

Enhanced analysis of gating latency in 0.35T MR‐linac through innovative time synchronization of a motion phantom and plastic scintillation detector

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose This study aims to evaluate how different gantry angles, breathing rates (BPM), cine image speeds, and tracking algorithms affect beam on/off latency and the subsequent impact on target dose for a 0.35T MR‐Linac with a 6 MV FFF beam.
Mateb Al Khalifa   +4 more
wiley   +1 more source

The burden of burnout: Understanding its prevalence and organizational drivers in medical physics

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Background Burnout is a work‐related syndrome characterized by increased levels of emotional exhaustion (EE) and depersonalization (DP) along with decreased levels of personal achievement. In the healthcare setting, higher burnout levels have been associated with negative impacts on personnel, an increased risk of errors, and a decrease in the
Deborah Schofield   +4 more
wiley   +1 more source

Towards better understanding of factors contributing to medical physicist well‐being in academic medical centers: A systems‐analysis approach

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract The well‐being of medical physicists can impact overall system performance, patient safety, and quality of patient care. There are limited formal assessments of factors contributing to physicists well‐being. Nine medical physicists at a US academic medical center were surveyed on 21 workplace factors, drawn from the National Academy of ...
Elizabeth Kwong   +13 more
wiley   +1 more source

Beam model development and clinical experience with RadCalc for treatment plan quality assurance in online adaptive workflow with an MR‐linac

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose The aim of this work was to report on the optimization, commissioning, and validation of a beam model using a commercial independent dose verification software RadCalc version 7.2 (Lifeline Software Inc, Tyler, TX, USA), along with 4 years of experience employing RadCalc for offline and online monitor unit (MU) verification on the ...
Urszula Jelen   +3 more
wiley   +1 more source

Demonstration of an enhanced dosing pattern for debulking large and bulky unresectable tumors via differential hole‐size spatially fractionated radiotherapy

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose/objective We propose a novel lattice deployment for spatially fractionated radiotherapy (SFRT) treatments. In this approach, a larger diameter high‐dose sphere is centrally placed in the bulky tumor mass and surrounded by smaller diameter high‐dose spheres.
Joshua Misa   +2 more
wiley   +1 more source

Dosimetric evaluation and clinical application of collimated apertures with proton beam line scanning in stereotactic radiotherapy

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose Stereotactic radiotherapy (SRT) is a highly effective treatment with precision for small, localized lesions. Proton therapy, characterized by the Bragg peak, offers superior dose conformity compared to photon‐based approaches. However, challenges remain in minimizing lateral penumbra and optimizing dose delivery, particularly for small
Chen‐Yu Chou   +3 more
wiley   +1 more source

Home - About - Disclaimer - Privacy