Results 11 to 20 of about 9,533 (217)
Simulation of reactive power regulation of DFIG [PDF]
Doubly fed induction generator (DFIG) wind power generation system is widely used in wind farm all over the world. Reactive power can be generated both in grid-side converter and generator-side converter of DFIG.
Zhu Yingfeng +5 more
doaj +2 more sources
This paper aims to explore a viable monitoring and management of active and reactive powers for a large-scale wind farm based on Doubly-Fed Induction Generators (DFIG) considering the voltage Fault-Ride-Through capability (FRT), especially Low-Voltage ...
Hammadi Laghridat +2 more
doaj +1 more source
Pemodelan Pembangkit Listrik Tenaga Bayu Kecepatan Variabel untuk Analisis Aliran Daya
Akhir-akhir ini, pemanfaatan energi angin melalui pembangkit listrik tenaga bayu (PLTB) kecepatan variabel untuk pembangkitan daya listrik telah mengalami peningkatan yang cukup signifikan.
Rudy Gianto
doaj +1 more source
Two-level DPC strategy based on FNN algorithm of DFIG-DRWT systems using two-level hysteresis controllers for reactive and active powers [PDF]
In this paper, a novel switching table (ST) of the twelve sectors direct power command (DPC) strategy of doubly-fed induction generator (DFIG) based dual rotor wind power (DRWP) is proposed using two-level hysteresis controllers for reactive and active ...
H. Benbouhenni
doaj +1 more source
Enhanced Fault Diagnosis of DFIG Converter Systems [PDF]
The converter is a crucial part of the doubly fed induction generator (DFIG) wind energy conversion system (WECS). Breakdown of the converter will lead to huge economic loss; this is relating to the downtime of the converter that will shut down the whole turbine-generator system and curtail the energy production.
Ibem, Chukwuemeka N. +2 more
openaire +2 more sources
Adaptive Gain Scheduling Control of Doubly Fed Induction Generator Based Wind Turbines to Improve Fault Ride Through Performance [PDF]
The Doubly-Fed Induction Generators (DFIG) based Wind Turbines (WT) are widely used in WTs connected to power systems. Traditionally the back-to-back converters are used in order to control the DFIG.
Ahmad Khajeh, Zahra Shabani
doaj +1 more source
The doubly fed induction generator (DFIG) has become increasingly popular for variable speed wind turbines because of the lower power electronics converter rating required. However, the small air gap of a DFIG causes it to be vulnerable to slight misalignment of the rotor which may cause a large unbalanced magnetic pull (UMP) to be exerted on the ...
Hawwooi Chuan +2 more
openaire +2 more sources
Wind energy conversion systems (WECSs) require a suitable control to maximise the power generated by wind turbines independently on the wind conditions.
Cherngchai Sompracha +2 more
doaj +1 more source
Wind Power Plant (PLTB) has received a lot of attention from the public, researchers, and the government because of its advantages and role in reducing the causes of environmental damage due to the generation of electrical energy.
Mus Ali Alsabah +3 more
doaj +1 more source
According to modern grid regulations, doubly fed induction generator (DFIG) needs to operate without losing synchronism during grid faults. But, severe fault leads to rise in stator and rotor current to a higher value and generator will get damaged ...
D.V.N. Ananth, G.V. Nagesh Kumar
doaj +1 more source

