Results 81 to 90 of about 2,187 (197)
Charged cellular polypropylene foams (i.e., ferro-or piezoelectrets) demonstrate high piezoelectric activity upon being electrically charged. When an external electric field is applied, dielectric barrier discharges (DBDs) occur, resulting in a ...
Harris, Scott +3 more
core +1 more source
Article is devoted to functioning of pulse electrotechnological installations on low frequency (0,1 Hz) and industry frequency. As an analog schemes of pulse relaxation generators for processes of electric erosion machining of metals are considered ...
E.A. Yakovlev +3 more
doaj
CONTINUOUS ONLINE MONITORING OF PD ACTIVITY IN THE MEDIUM VOLTAGE DISTRIBUTION NETWORK
Partial discharges (PD) occur as a result of dielectric breakdown in electrical ...
Patrick Mulroy, Ian Gilbert
core
Surface tracking in the inter-phase region of large transformers
Transmission and distribution operators throughout the world manage significant populations of ageing large transformers which use mineral oil and paper as the dielectric insulation.
Mitchinson, Peter Mark
core +1 more source
In this study, a one-dimensional fluid model is employed to analyze the electrical and physicochemical properties of dielectric barrier discharges (DBDs) in pure CO₂ and CO₂/Ar mixtures at atmospheric pressure.
Mohamed Chenoui +2 more
doaj +1 more source
The partial discharge (PD) process in liquid dielectrics is influenced by several factors. Although the PD current contains the information representing the discharge process during the PD event, it is difficult to determine the detailed dynamics of what
Qing Yang +9 more
core +1 more source
Dielectrics for high temperature superconducting applications
This thesis is concerned with the development of condition monitoring for future design of high temperature superconducting (HTS) power apparatus. In particular, the use of UHF sensing for detecting PD activity within HTS has been investigated.
Truong, L.H.
core +1 more source
On the Condition Required for Discharge and Dielectric Breakdown
HAYASHI, M., ANDO, N.
openaire +1 more source
Adaptive Simulation of Electrical Discharges
Figure 1: Simulation of a cloud-to-ground lightning. The breakdown pattern is computed iteratively using the dielectric breakdown model on an adaptively sampled grid. We present an adaptive animation method for electrical discharges.
Bernd Bickel, Martin Wicke, Markus Gross
core
SURFACE CHARGE INFLUENCE ON THE BREAKDOWN VOLTAGE IN HE
Electrostatic charging can occur by the accumulation of charge carriers on dielectric surfaces due to electrical discharges. The charges accumulated on dielectric materials in an electrical discharge device change the potential distribution, so that the ...
Vladoiu, Rodica +3 more
core

