Results 61 to 70 of about 5,009,115 (304)

A Novel Compensation for Differential Protection

open access: yes, 2019
Power flow through a power system corridor is largely a function of the angle difference between the voltage phasors at two ends. Phase Shifting Transformers (PST) are placed in series with important lines at one end or combined with power transformers, to regulate the voltage angle difference between two ends of a power corridor.
Viona Catterson, Stark, Artur
openaire   +2 more sources

IMPDH inhibition enhances cytarabine efficacy in SAMHD1‐expressing leukaemia cells via guanine nucleotide depletion

open access: yesMolecular Oncology, EarlyView.
Cytarabine is a key therapy for acute myeloid leukaemia (AML), but its efficacy is limited by the dNTPase SAMHD1, which hydrolyses its active metabolite. Screening nucleotide biosynthesis inhibitors revealed that IMPDH inhibitors selectively sensitise SAMHD1‐proficient AML cells to cytarabine.
Miriam Yagüe‐Capilla   +9 more
wiley   +1 more source

Keratin 19 as a prognostic marker and contributing factor of metastasis and chemoresistance in high‐grade serous ovarian cancer

open access: yesMolecular Oncology, EarlyView.
Keratin 19 (KRT19) is overexpressed in high‐grade serous ovarian cancer with high levels of Kallikrein‐related peptidases (KLK) 4–7 and is associated with poor survival. In vivo analyses demonstrate that elevated KRT19 increases peritoneal tumour burden.
Sophia Bielesch   +13 more
wiley   +1 more source

Validation of mathematical model of differential protection [PDF]

open access: yes, 2014
Comparison of results of mathematical modeling and field tests of a transformer differential protection is presented in this paper. An inrush current mode, external two-phase and three-phase faults are considered.
Wegierek, P.   +4 more
core  

Dual PI3K/AKT and CDK4/6 inhibition reveals selective sensitivity in an SHH medulloblastoma stem cell model

open access: yesMolecular Oncology, EarlyView.
Targeted therapy was evaluated in SHH medulloblastoma using neuroepithelial stem cell (NES) and tumor‐derived NES‐like (tNES) models in 2D monolayers and 3D spheroids. PI3K, AKT, and CDK4/6 inhibitors had minimal effects in NES but markedly reduced viability and growth and induced apoptosis in tNES cells, revealing distinct therapeutic vulnerabilities.
Monika Lukoseviciute   +4 more
wiley   +1 more source

Secure Protection Interface Communication for Line Current Differential Protection Systems

open access: yes, 2018
A well-known and established power system protection system is line current differential protection. In order to set up such a protection system, communication between the protection relays, i.e. the protection interface, is required.
Aichhorn, Andreas
core   +1 more source

Hippo pathway at the crossroads of stemness and therapeutic resistance in breast cancer

open access: yesMolecular Oncology, EarlyView.
Dysregulation of the Hippo pathway drives nuclear accumulation of YAP/TAZ, activating stemness‐related transcriptional programs that sustain breast cancer stemness and fuel therapeutic resistance across subtypes, underscoring Hippo signaling as a targetable vulnerability. Figure created and edited with BioRender.com.
Giulia Schiavoni   +11 more
wiley   +1 more source

Busbar differential protection of high voltage substations

open access: yes, 2022
U ovom radu analizirane su visokoimpedantna i niskoimpedantna diferencijalna zaštita sabirnica koje se koriste u elektroenergetskom sustavu. Osim teorijskog objašnjenja, prikazan je primjer pomoću uređaja 7SS85 kojem je glavna funkcija zaštita sabirnica.
Grizelj, Tea
core   +1 more source

"National Adversity: Managing Insurance and Protection" [PDF]

open access: yes
This paper concerns self-insurance and self-protection that countries may implement at a national level in pursuit of their security. The distinctions self-insurance, self-protection, and market insurance were first made by Ehrlich and Becker (1972 ...
Toshihiro Ihori, Martin McGuireb
core  

System level tests of transformer differential protection using an IEC 61850 process bus

open access: yes, 2013
The IEC 61850 family of standards for substation communication systems were released in the early 2000s, and include IEC 61850-8-1 and IEC 61850-9-2 that enable Ethernet to be used for process-level connections between transmission substation switchyards
Taylor, Richard R.   +3 more
core   +1 more source

Home - About - Disclaimer - Privacy