Results 91 to 100 of about 2,051,359 (297)
Electrochemical study of natamycin - analytical application to pharmaceutical dosage forms by differential pulse voltammetry [PDF]
The electrochemical oxidation and determination of natamycin has been carried out at a carbon paste electrode in aqueous solutions in the pH range of 2.5-10.30 by cyclic and differential pulse voltammetry. Best results were obtained with the differential
YILMAZ, SELAHATTİN +4 more
core +2 more sources
Variations in polymer conformations of unsaturated poly(n‐alkyl esters) driven by monomer‐level stereochemistry directly govern Li+ solvation structures in polymer host matrices. The synergistic strategies of polymer conformation control, UV‐induced interchain crosslinking, and end‐group fluorination are implemented for engineering advanced solid ...
Hyun Jun Song +11 more
wiley +1 more source
A new and simple approach for carbaryl determination in natural sample was proposed using Low Silica X (LSX) zeolite modified carbon paste electrode.
Fatima Ezzahra Salih +6 more
doaj +1 more source
In the present work, sensitive and selective determination of teriflunomide (Trf) on an edge plane pyrolytic graphite electrode (EPPGE) using differential pulse voltammetry (DPV) is presented for the first time.
Sławomira Skrzypek +3 more
core +1 more source
Neuromorphic Near‐Sensor and In‐Sensor Computing Enabled by Next‐Generation Material‐Based Sensors
This Review presents a structural framework that classifies neuromorphic sensing into near‐sensor and in‐sensor architectures, clarifying physical coupling between sensing and computation. The framework connects neural and synaptic device functions with recent advances in optical, mechanical, and chemical sensing, compares energy consumption and ...
Su Yeon Jung +7 more
wiley +1 more source
Simultaneous Determination of Trace Lead (II), Cadmium (II) and Cobalt (II) by Differential Pulse Anodic Stripping Voltammetry Using Polyacrylic acid/Glassy Carbon Electrode [PDF]
Polyacrylic acid/Glassy carbon electrode (PAA/GCE) was employed for the determination of lead(II), cadmium(II) and cobalt(II). With differential pulse anodic stripping voltammetry, the following optimal conditions were determined: Deposition potential ...
Onyatta, John O. +3 more
core +1 more source
Differential pulse anoding voltammetric determination of torasemide using carbon paste electrode
Torasemide electrochemical behavior at a carbon paste electrode was investigated and optimized using cyclic and differential pulse voltammetry in 0.04 mol/L Britton-Robinson (BR) buffer pH 2.8.
Sayed I. M. Zayed, Ibrahim H. I. Habib
doaj +1 more source
Voltammetric Determination of Tenoxicam in Drug Formulation at Modified Glassy Carbon Electrode
In this study, the electrocatalytic reduction of tenoxicam (TNX) was studied on a 4-aminobenzene sulfonic acid (4-ABSA) modified glassy carbon (GC) electrode using cyclic voltammetry (CV) and differential pulse voltammetry (DPV) techniques.
Murat Sadikoglu, Ahmet Cabuk
doaj +1 more source
We carried out the determination of cytochrome C, in solution and in the adsorbed state, using differential pulse voltammetry (DPV). The results obtained with DPV were compared with those obtained using cyclic voltammetry (CV).
Curulli A +4 more
core
Multiferroic order parameters – polarization, magnetization, and ferroelastic strain – are positioned as dynamic design variables for batteries. Their mechanistic roles, practical tuning through fabrication and external fields, and ferroic‐resolved characterization routes are unified into a closed‐loop framework, revealing how coupled ferroic responses
Jiaqi Su +13 more
wiley +1 more source

