Results 241 to 250 of about 4,529,228 (280)
Some of the next articles are maybe not open access.
Investigation of dispersed phase holdup in a Tenova pulsed liquid-liquid extraction column
Journal of the Taiwan Institute of Chemical Engineers, 2023Neshat Rahimpour +3 more
semanticscholar +2 more sources
Experimental investigation on dispersed phase holdup in an L-shape pulsed packed extraction column
Progress in Nuclear Energy, 2021Abstract In this study, the dispersed phase hold-up has been investigated in a pilot plant of a new type of extraction column entitled “L-shaped pulsed packed extraction column” by using two liquid systems of toluene/acetone/water and n-butyl/acetone/water in the presence of mass transfer in two directions.
Sajad Khooshechin +3 more
semanticscholar +2 more sources
Dispersed Phase Holdup in a Tall and Low Plate Free Area Liquid Pulsed Sieve-Plate Extraction Column
Separation Science and Technology, 2013S. Y. Khawaja +4 more
exaly +2 more sources
Separation Science and Technology, 2021
This research aims to optimize the influential hydrodynamic parameters in liquid-liquid extraction columns for three different systems of butanol–water, n-butylacetate–water, and toluene–water recommended by the European Federation of Chemical ...
A. Hemmati, A. Ghaemi, M. Asadollahzadeh
semanticscholar +1 more source
This research aims to optimize the influential hydrodynamic parameters in liquid-liquid extraction columns for three different systems of butanol–water, n-butylacetate–water, and toluene–water recommended by the European Federation of Chemical ...
A. Hemmati, A. Ghaemi, M. Asadollahzadeh
semanticscholar +1 more source
Ultrasonic technique for dispersed-phase holdup measurements
Industrial & Engineering Chemistry Research, 1987Mesure du temps de transit d'un train de pulsations ultrasonores, dans une colonne d'extraction liquide-liquide. Un modele de moyenne temporelle permet d'evaluer la retenue de la phase dispersee a partir du temps de transmission global des pulsations sonores.
J. C. Bonnet, L. Tavlarides
semanticscholar +2 more sources
Dispersed phase holdup and mass transfer in liquid pulsed column
Bioprocess Engineering, 1998Dispersed phase holdup and drop velocity relative to the continuous phase are of fundamental importance in the development and operation of pulsed columns. Pulsed columns find application as biochemical reactors and in liquid-liquid extraction. The paper presents experimental data and its analysis covering dispersed phase holdup, slip velocity and mass
D. Venkatanarasaiah, Y. B. G. Varma
semanticscholar +2 more sources
Dispersed‐phase holdup in a rotating disk extraction column
AIChE Journal, 1961AbstractA study has been made of the effect of column geometry and flow condition upon the dispersed‐phase holdup in an rotating disk type of extraction column. Variables investigated were stator opening, disk diameter, compartment height, rotor speed, and flow rates of the dispersed and continuous phases.
E.-Y. Kung, R. Beckmann
semanticscholar +2 more sources
Dispersed phase holdup and drop size distributions in reciprocating plate columns
The Canadian Journal of Chemical Engineering, 1983AbstractThe paper covers an experimental and theoretical investigation of the dispersed phase holdup and drop size distribution for gas‐liquid and liquid‐liquid counter‐current flow in reciprocating plate columns provided with plates having small hole size and free area. The response of the reciprocating plate column is similar to that of liquid‐pulsed
N. V. Rama Rao +2 more
semanticscholar +2 more sources
, 2020
A parametric study of the dispersed phase holdup, specific power consumption (P) and axial drop size distribution (ADSD) in a pulsed disc and doughnut column have been carried out with 30% Tri-Butyl Phosphate- 0.01 M nitric acid system.
V. Sinha, T. Vincent
semanticscholar +1 more source
A parametric study of the dispersed phase holdup, specific power consumption (P) and axial drop size distribution (ADSD) in a pulsed disc and doughnut column have been carried out with 30% Tri-Butyl Phosphate- 0.01 M nitric acid system.
V. Sinha, T. Vincent
semanticscholar +1 more source

