Adaptive Distance Protection for Microgrids [PDF]

open access: yesIECON 2015 - 41st Annual Conference of the IEEE Industrial Electronics Society, 2015
Due to the increasing penetration of distributed generation resources, more and more microgrids can be found in distribution systems. This paper proposes a phasor measurement unit based distance protection strategy for microgrids in distribution system ...
Guerrero, Josep M.   +3 more
core   +5 more sources

Distance protection algorithm based differential equation

open access: yesRevista Técnica de la Facultad de Ingeniería, 2006
El algoritmo de la protección de distancia basado en la ecuación diferencial determina la ubicación de una falla en función de los valores de la resistencia y reactancia de línea que existen en el momento de su ocurrencia.
William José Osal Herrera   +1 more
doaj   +4 more sources

Distance Protection of Series Capacitor Compensated Lines: Practical Considerations, Industrial Status and Development

open access: yesElectricity, 2021
The introduction of series capacitors in transmission lines causes problems in terms of reliability and the security of distance protection relays. As distance protection is widely used in the transmission network, the challenge of applying it to series ...
Md Tanbhir Hoq, Nathaniel Taylor
doaj   +1 more source

Transmission Line Distance Protection Under Current Transformer Saturation

open access: yesJournal of Modern Power Systems and Clean Energy, 2021
Conventional transmission line distance protection approaches are subject to malfunction under reverse fault-induced current transformer (CT) saturation for the typically employed breaker-and-a-half configuration.
Yuping Zheng   +5 more
doaj   +1 more source

Power-Based Concept for Current Injection by Inverter-Interfaced Distributed Generations during Transmission-Network Faults

open access: yesApplied Sciences, 2021
This paper analyzes the influence of inverter-interfaced distributed generations’ (IIDGs) response during transmission network faults. The simplest and safest solution is to switch IIDGs off during network faults without impacting the network voltages. A
Boštjan Polajžer   +3 more
doaj   +1 more source

Distance Relay Over-reach Prevention by Impedance Starter Adjustment in: Ph-to-Ph Faults [PDF]

open access: yesInternational Journal of Research and Technology in Electrical Industry, 2023
The protection of transmission and sub-transmission lines is conducted by overcurrent, line differential and distance protections among which the use of distance protection is very common.Mal-operation of protection equipment, including distance ...
Ehsan Karami   +2 more
doaj   +1 more source

Calculation of specific operating modes of relay protection for AC traction networks

open access: yesВестник Научно-исследовательского института железнодорожного транспорта, 2020
Relay protection of traction networks against short-circuit currents in alternating current sections should have both selectivity and speed. However, in areas with an increased probability of burnout of contact wires during a short circuit, selectivity ...
K. S. Subkhanverdiev
doaj   +1 more source

Mutual Coupling Compensation Techniques Used for Distance Protection of Parallel Lines

open access: yesEnergies, 2021
When a distance relay protects a transmission line located on a dual circuit tower, a coupling effect will occur between the two circuits. Transposition of the circuits can reduce the mutual impedances, but this does not cater to the zero-sequence mutual
Michael O Donovan   +3 more
doaj   +1 more source

Misoperation analysis and logic optimization of distance protection section I of polygonal impedance

open access: yesZhejiang dianli, 2022
The widely used distance protection is of great significance to operation reliability of power grid. The paper cites an example of misoperation of distance protection section I and points out the defects of action zone configuration of polygonal ...
QIAN Zhengxu   +5 more
doaj   +1 more source

An Adaptive Protection Scheme for Power Systems Considering the Effects of HVDC Interfaced Distributed Generations

open access: yesIEEE Access, 2022
Distributed Generations are usually connected to the ac grid through HVDC transmission systems. However, due to the current injected by the grid-side voltage source converter (GVSC), the voltage drop after a short-circuit fault will be partly compensated.
Jipu Gao   +4 more
doaj   +1 more source