Estimation of effective dose from CT scanning using dose length product in a Nepalese hospital
Keywords: Effective dose, Dose Length Product, Computed Tomography Dose Index volume, Dose Reference Level Abstract Aim: The aim of this study was to estimate the effective doses from CT scans using Dose Length Product (DLP) in a Nepalese hospital ...
Pooja Shah
doaj +3 more sources
Correlation of Anteroposterior Diameter of Abdomen with CT Dose Index and Dose Length Product in Abdomen CT ScanA Retrospective Study [PDF]
Introduction: Computed Tomography (CT) remains an important tool in diagnostic imaging. Establishment of Diagnostic Reference Levels (DRL) is highly recommended in order to have a check on the radiation exposure. Aim: To study the correlation between
Ramesh Parthasarathy +4 more
doaj +2 more sources
Computed tomography (CT) has had a massive impact on diagnostic radiology over the past few decades. Serious concerns exist because of the increase in the effective radiation dose associated with CT scans, which could pose significant health risks. In CT,
Elfatih Abuelhia +11 more
doaj +2 more sources
Dose length product to effective dose coefficients in children. [PDF]
Abstract Background The most accurate method for estimating effective dose (the most widely understood metric for tracking patient radiation exposure) from computed tomography (CT) requires time-intensive Monte Carlo simulation.
Chu PW +10 more
europepmc +5 more sources
Correction to: Dose length product to effective dose coefficients in children. [PDF]
Chu PW +10 more
europepmc +2 more sources
Computed Tomography Dose in Paediatric Care: Simple Dose Estimation Using Dose Length Product Conversion Coefficients. [PDF]
The use of multislice computed tomography (MSCT) is increasing worldwide; at the same time, there is a growing awareness of the future risk of cancer associated with greater exposure to radiation. Therefore, there is a need for an accessible method of effective dose estimation.
Tap NHM +5 more
europepmc +3 more sources
Converting dose-length product to effective dose at CT. [PDF]
To determine effective dose (ED) per unit dose-length product (DLP) conversion factors for computed tomographic (CT) dosimetry.A CT dosimetry spreadsheet was used to compute patient ED values and corresponding DLP values. The ratio of ED to DLP was determined with 16-section CT scanners from four vendors, as well as with five models from one ...
Huda W, Ogden KM, Khorasani MR.
europepmc +4 more sources
Today in the Russian Federation, the existing method for assessing patients` effective doses during computed tomography in the form of conversion coefficients from the dose-length product provides for the area from the head to the upper third of the ...
P. S. Druzhinina +5 more
doaj +2 more sources
A method for calculating the dose length product from CT DICOM images. [PDF]
The dosimetric calculations in CT examinations are currently based on two quantities: the volume weighted CT dose index (CTDI(vol)) and the dose-length product (DLP). The first quantity is dependent on the exposure factors, scan field of view, collimation and pitch factor selections, whereas the second is additionally dependent on the scan length.In ...
Tsalafoutas IA, Metallidis SI.
europepmc +4 more sources
Cardiac-Specific Conversion Factors to Estimate Radiation Effective Dose From Dose-Length Product in Computed Tomography. [PDF]
This study sought to determine updated conversion factors (k-factors) that would enable accurate estimation of radiation effective dose (ED) for coronary computed tomography angiography (CTA) and calcium scoring performed on 12 contemporary scanner models and current clinical cardiac protocols and to compare these methods to the standard chest k-factor
Trattner S +12 more
europepmc +3 more sources