Results 181 to 190 of about 702,273 (272)

Improving organ dose sparing in left‐sided breast cancer with yaw‐limited volumetric modulated arc therapy: A dosimetric comparison to conventional and intensity modulated radiation therapy approaches

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Background To assess the dose‐sparing capabilities of a yaw‐limited volumetric modulated arc therapy (YL_VMAT) beam setup for adjacent organs at risk (OAR) in comparison with 3D‐conventional radiation therapy (3D‐CRT), intensity‐modulated radiation therapy (IMRT) and conventional VMAT for radiation therapy in left‐sided breast cancer patients.
Gerhard Pollul   +4 more
wiley   +1 more source

Commissioning of Halcyon enhanced leaf model in the Eclipse treatment planning system: Focus on simple slit fields and VMAT dose calculation

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose The dual‐layer multileaf collimator (MLC) in Halcyon adds complexities to the dose calculation process owing to the variability of dosimetric characteristics with leaf motion. Recently, an enhanced leaf model (ELM) was developed to refine the MLC model in the Eclipse treatment planning system. This study investigates the performance of
Ryohei Miyasaka   +6 more
wiley   +1 more source

Adherence Monitoring and Drug Surveillance in Chronic Opioid Therapy [PDF]

open access: bronze, 2000
Scott M. Fishman   +5 more
openalex   +1 more source

Closing the gap in plan quality: Leveraging deep‐learning dose prediction for adaptive radiotherapy

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose Balancing quality and efficiency has been a challenge for online adaptive therapy. Most systems start the online re‐optimization with the original planning goals. While some systems allow planners to modify the planning goals, achieving a high‐quality plan within time constraints remains a common barrier.
Sean J. Domal   +9 more
wiley   +1 more source

Adalimumab Autoantibodies in Uveitis Patients: Do We Need Routine Drug Monitoring? [PDF]

open access: yesBiomedicines
Zur Bonsen LS   +4 more
europepmc   +1 more source

Stereotactic radiotherapy for metastatic brain tumors: A comparative analysis of dose distributions among VMAT, Helical TomoTherapy, CyberKnife, Gamma Knife, and ZAP‐X

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract This study evaluates various radiotherapy techniques for treating metastatic brain tumor (BT), focusing on non‐coplanar volumetric modulated arc radiotherapy (NC‐VMAT), coplanar VMAT (C‐VMAT), Helical TomoTherapy (HT), CyberKnife (CK), Gamma Knife (GK), and ZAP‐X.
Toshihiro Suzuki   +9 more
wiley   +1 more source