Results 161 to 170 of about 734,352 (247)

Advantages and limitations of navigation‐based multicriteria optimization (MCO) in selectively sparing pharyngeal constrictor muscles in head and neck radiotherapy treatment planning

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose Sparing pharyngeal constrictor muscles (PCMs) during radiotherapy improves patient‐reported swallowing function. This study aimed to explore the feasibility of integrating knowledge‐based planning (KBP) with multicriteria optimization (MCO) in Eclipse v18.0 to selectively spare PCM, quantify the required trade‐off in prophylactic ...
Laura K. Howard   +3 more
wiley   +1 more source

Developing reference plans for evaluating global clinical trials credentialing and PSQA systems

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose To develop a practical framework for creating a diverse set of validated reference plans (varying in complexity) and implement a workflow to introduce beam modeling, calibration, and delivery errors into the reference cohort to test and compare various dosimetry audit methodologies.
Fre'Etta M. D. Brooks   +13 more
wiley   +1 more source

Determination of drugs used in combined cardiovascular therapy

open access: yes, 2011
Cardiovascular diseases are nowadays the first cause of mortality worldwide, causing around the 30% of global deaths each year. The risk of suffering from cardiovascular illnesses is strongly related to some factors such as hypertension, high cholesterol levels, diabetes, obesity The combination of these different risk factors is known as metabolic ...
openaire   +1 more source

The edge visualization metric: Quantifying the improvement of lung SBRT target definition with 4D CBCT

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose Four‐dimensional cone‐beam CT (4D CBCT) incorporates oversampling of 3D data to reconstruct multi‐phase CBCT data sets representing distinct phases of the breathing cycle based on a diaphragmatic correlate of respiratory motion. Motion artifacts and blurring can be reduced relative to three‐dimensional cone‐beam (3D CBCT), allowing ...
Colton Baley   +4 more
wiley   +1 more source

Energy dependence of the GAFCHROMIC LD‐V1 in the diagnostic radiographic modalities

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract The GAFCHROMIC LD‐V1 radiochromic film is widely used in dosimetry because it can provide high‐resolution two‐dimensional dose distributions without processing. This study aimed to evaluate the response characteristics at different effective energies, from the low‐energy range of mammography to the high‐energy range of computed tomography. Net
Tatsuhiro Gotanda   +9 more
wiley   +1 more source

AAPM medical physics practice guideline 13.a: HDR brachytherapy, part B

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract The goal of this report is to assist the clinical medical physicist in assuring that key quality standards and practice considerations are met to ensure safe, reliable, and reproducible high dose rate (HDR) brachytherapy (BT) treatment. This guideline has been developed to provide appropriate minimum standards for such services.
Susan L. Richardson   +8 more
wiley   +1 more source

Home - About - Disclaimer - Privacy