Results 181 to 190 of about 51,266 (223)

Assessing proton plans with three different beam delivery systems versus photon plans for head and neck tumors

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose To compare plan quality among photon volumetric modulated arc therapy (VMAT) and intensity‐modulated proton therapy (IMPT) with robustness using three different proton beam delivery systems with various spot size (σ) ranges: cyclotron‐generated proton beams (CPBs) (σ: 2.7–7.0 mm), linear accelerator proton beams (LPBs) (σ: 2.9–5.5 mm),
Tara Gray   +9 more
wiley   +1 more source

Left hippocampus sparing model for glioblastoma radiotherapy by utilizing knowledge‐based planning and multi‐criteria optimization

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose Results of a prospective, randomized controlled trial at our institute demonstrate an association between the dose to the left hippocampus and neurocognitive decline post‐radiotherapy for patients with glioblastoma. To minimize the dose to the left hippocampus, a left hippocampus sparing model was created using RapidPlan (RP) and multi‐
Shima Y. Tari   +9 more
wiley   +1 more source

IROC phantoms accurately detect MLC delivery errors

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose We evaluated the impact of random and whole‐bank multileaf collimator (MLC) delivery errors on dosimetric delivery accuracy in the Imaging and Radiation Oncology Core (IROC) phantom audits, as well as differences in delivery accuracy between the IROC phantom prescription and typical clinical fraction sizes.
Sharbacha S. Edward   +5 more
wiley   +1 more source

The effect of multi‐leaf collimator leaf width on VMAT treatment plan quality

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Background The advent of volumetric modulated arc therapy (VMAT) in radiotherapy has made it one of the most commonly used techniques in clinical practice. VMAT is the delivery of intensity modulated radiation therapy (IMRT) while the gantry is in motion, and existing literature has shown it has decreased treatment delivery times and the ...
Gregory Sadharanu Peiris   +3 more
wiley   +1 more source

JACMP 2015 – 2019

open access: yes
Journal of Applied Clinical Medical Physics, EarlyView.
Per. H. Halvorsen
wiley   +1 more source
Some of the next articles are maybe not open access.

Related searches:

Immunosuppressive drug therapy

Current Opinion in Rheumatology, 1989
Interstitial lung disease frequently complicates rheumatic disorders, especially polymyositis-dermatomyositis, rheumatoid arthritis, systemic sclerosis, and mixed connective tissue disease. In this article, we review the current data supporting the use of azathioprine, cyclophosphamide, chlorambucil, cyclosporine, and methotrexate in the management of ...
W J, McCune, D K, Vallance, J P, Lynch
openaire   +5 more sources

Drug therapy

The Lancet, 1995
Drug therapy for individuals of any age is difficult but prescribing for older patients offers special challenges. Older people take about three times as many prescription medications as younger individuals do, mainly because of their increased prevalence of chronic medical conditions.
Rochon, Paula A., Gurwitz, Jerry H.
openaire   +3 more sources

Drug Therapy: Rifaximin

Hepatology, 2010
[No abstract available]
J. S. Bajaj, RIGGIO, Oliviero
openaire   +4 more sources

Drug Therapy

2017
This chapter first summarizes the therapy of addiction disorder, and elaborates on the progress of medication. First, the difference between dependency and addiction are introduced. The basic principles of the therapy of substance and non-substance addiction are then put forward.
Ri-Hui, He, Ran, Tao
openaire   +2 more sources

Home - About - Disclaimer - Privacy