Results 231 to 240 of about 6,141,374 (292)

Blood Cell‐Camouflaged Liquid Metal Nanoconjugates Orchestrate Treg Depletion and STING‐Amplified Photothermal Immunity for Metastatic Triple‐Negative Breast Cancer Therapy

open access: yesAdvanced Science, EarlyView.
Whole‐blood biomimetic engineering transforms liquid metal nanoparticles into a tripartite immunotherapeutic platform that orchestrates regulatory T‐cell depletion, photothermal‐induced immunogenic cell death, and activation of the stimulator of interferon genes pathway.
Nina Sang, Eijiro Miyako
wiley   +1 more source

Van der Waals Heterostructures for Next‐Generation Spintronics: Multiferroic‐Mediated Magnetoelectric Properties

open access: yesAdvanced Science, EarlyView.
As CMOS technology approaches fundamental energy limits, new paradigms for low‐power information processing are required. Magnetic systems are attractive for their spin transport, yet current‐induced magnetization control is energy inefficient. Multiferroic heterostructures enable energy‐efficient electric field manipulation of magnetism.
Donghyeon Lee   +3 more
wiley   +1 more source

Aggregation‐Controlled Triplet Exciton Regulation Enables Single‐Emitter Color‐Evolving Afterglow

open access: yesAdvanced Science, EarlyView.
A single‐emitter system based on DTP‐R luminophores enables time‐evolving afterglow through aggregation‐regulated excited‐state dynamics. The coexistence and suppression of delayed fluorescence and phosphorescence are controlled via concentration tuning and host‐guest engineering, revealing the RISC origin of delayed fluorescence and enabling ...
Yu Zhang   +14 more
wiley   +1 more source

Supercapacitor Safety: Overcharge‐Induced Failure Mechanisms in Electrochemical Double‐Layer Capacitors

open access: yesAdvanced Science, EarlyView.
Time‐resolved synchrotron radiography reveals the internal evolution of electrochemical double‐layer capacitors under abusive overcharge. EDLCs are shown to follow a thermally driven failure pathway involving electrolyte decomposition, gas generation, and structural collapse, distinct from chemically driven thermal runaway effects of Lithium‐ion ...
Thomas Dore   +19 more
wiley   +1 more source

Advances of dual source, dual-energy imaging in postmortem CT

open access: yesEuropean Journal of Radiology, 2008
This paper focuses on the use of multi-detector row dual-energy computed tomography (DECT) in the evaluation of postmortal examinations. The use of dual energy moves postmortem CT to an entirely new dimension of diagnostic sensitivity where contrast in the image is not merely limited to X-ray attenuation differences, but may include elements of ...
Persson, Anders   +3 more
openaire   +4 more sources

Dual-Energy and Dual-Source CT: Is There a Role in the Abdomen and Pelvis?

Radiologic Clinics of North America, 2009
Dual-energy CT refers to the use of CT data representing two different energy spectra and allows for the possibility of differentiating and classifying tissue to obtain material-specific images. Dual-energy CT data can be acquired using various CT hardware platforms, with numerous approaches also existing for display of anatomic and material-specific ...
Cynthia H McCollough   +2 more
exaly   +3 more sources

A new scheme and reconstruction algorithm for dual source circular CT

open access: yes2006 International Conference of the IEEE Engineering in Medicine and Biology Society, 2006
Circular cone beam scanning has been a most popular scheme for computed tomography (CT) imaging, which is simple and can achieve symmetric projection data of the interested object. Many algorithms have been developed for circular cone beam CT. Many of these are FDK type algorithms, which can achieve good reconstruction quality when cone angle is small ...
Ming Yan 0002   +2 more
openaire   +4 more sources

Quantitative assessment of motion effects in dual-source dual energy CT and dual-source photon-counting detector CT

Medical Imaging 2022: Physics of Medical Imaging, 2022
Conventional dual-source CT scanners can be used to either provide better temporal resolution or dual-energy imaging, but not both at the same time. This presents a dilemma in cardiac CT as both high temporal resolution and multi-energy imaging are desirable.
Zaki, Ahmed   +4 more
openaire   +2 more sources

Technical principles of dual source CT

European Journal of Radiology, 2008
During the past years, multi-detector row CT (MDCT) has evolved into clinical practice with a rapid increase of the number of detector slices. Today's 64 slice CT systems allow whole-body examinations with sub-millimeter resolution in short scan times. As an alternative to adding even more detector slices, we describe the system concept and design of a
Martin, Petersilka   +4 more
openaire   +2 more sources

Home - About - Disclaimer - Privacy