Noise reduction in dual-source CT scanning

SPIE Proceedings, 2011
With dual source CT, special attention has to be paid to scattered radiation. X-ray quanta from the second source (tube B) get scattered from the object in the scan field and are registered by the first detector (detector A) and vice versa ("cross scattered radiation").
M. Petersilka   +2 more
openaire   +1 more source

Flash imaging in dual source CT (DSCT)

SPIE Proceedings, 2009
ABSTRACT We present new acquisition modes of a recently introduced dual-source computed tomography (DSCT) system equipped with two X-ray tubes and two corresponding detectors, mounted onto the rotating gantry with an angular offset of typically 90° . Due to the simultaneous acquisition of complementary data, the minimum exposure time is reduced by a ...
H. Bruder   +9 more
openaire   +1 more source

Principle and applications of dual source CT

SPIE Proceedings, 2008
Dual source CT (DSCT) has the potential to solve remaining limitations of conventional multi-detector row CT (MDCT)-scanners, such as insufficient temporal resolution for ECG-controlled cardiac imaging. A DSCT is equipped with two X-ray tubes and two corresponding detectors that are mounted onto the rotating gantry with an angular offset of 90°.
openaire   +1 more source

Radiation Dose at Coronary CT Angiography: Second-Generation Dual-Source CT Versus Single-Source 64-MDCT and First-Generation Dual-Source CT

American Journal of Roentgenology, 2011
The purpose of this study was to assess the radiation doses of different coronary CTA (CTA) protocols: second-generation dual-source 128-MDCT, first-generation dual-source 64-MDCT, and single-source 64-MDCT.Thermoluminescent dosimetry was used to determine scanner-specific dose coefficients for standard coronary CTA of an anthropomorphic phantom. These
Christian, Fink   +9 more
openaire   +2 more sources

Cardiac inflammatory myofibroblastic tumor: Evaluation with dual-source CT

Journal of Cardiovascular Computed Tomography, 2009
We present a case of inflammatory myofibroblastic tumor that was evaluated with retrospectively gated dual-source cardiac CT. Imaging features included a broad-based attachment, lobulated contour, and patchy areas of contrast medium enhancement that persisted on delayed imaging.
Edward T D, Hoey   +3 more
openaire   +2 more sources

The predictive role of dual source CT for esophageal foreign bodies

American Journal of Otolaryngology, 2014
Esophageal foreign bodies can be a danger to a patient's life. Flexible or rigid endoscopy is a commonly used type of invasive investigation for these, and radiological examinations are also useful.Series of reports.Multi-slice spiral CT (MSCT) can confirm and locate most foreign bodies.
Zhenghua, Zhu   +5 more
openaire   +2 more sources

Low dose dual-source CT angiography of the thoracic aorta

The International Journal of Cardiovascular Imaging, 2010
The purpose of this study was to investigate the effects of a prospective ECG-gated, low kilovoltage and low mAs protocol on image quality and radiation dose when acquiring CT angiography of the thoracic aorta (CTTA). Sixty patients with a body mass index (BMI) of less than 30 and a heart rate of less than 100 beats per minute (bpm) were included in ...
Cormac, Farrelly   +6 more
openaire   +2 more sources

[Dual-source CT coronary angiography].

Revista de medicina de la Universidad de Navarra, 2008
Multidetector computed tomography (MDCT) has been demonstrated to be a very useful technique to non-invasively study coronary arteries. Despite the high spatial and temporal resolution of 64-slice MDCT scanners, this technique has several limitations.
G, Bastarrika, M, Arraiza, J, Pueyo
openaire   +1 more source

Cardiovascular imaging in pediatric patients using dual source CT

Journal of Cardiovascular Computed Tomography, 2016
Cardiovascular CT acquisition protocol optimization in pediatric patients, including newborns is often challenging. This might be due to non-cooperative patients, the complexity and variety of diseases and the need for stringent dose minimization. Motion artifacts caused by voluntary and involuntary motion are most frequently seen in cardiac imaging ...
Ronald Booij   +7 more
openaire   +2 more sources

Technical Aspects of Dual Energy CT with Dual Source CT Systems

2015
This article describes technical principles and clinical applications of dual energy (DE) scanning with dual source CT (DSCT) systems, with a focus on vascular and cardiac applications. DSCT systems acquire DE data by simultaneously operating both x-ray tubes at different x-ray tube voltages (different kV).
Thomas Flohr, Bernhard Schmidt
openaire   +1 more source