Strategies for scatter correction in dual source CT
Medical Physics, 2010Purpose:Dual source CT (DSCT) systems utilize two measurement systems (A) and (B) offset by about 90°. A special challenge in DSCT is cross‐scattered radiation, i.e., scattered radiation from x‐ray tube (B) detected in detector (A) and vice versa. Cross‐scattered radiation can produce artifacts and degrade the contrast‐to‐noise ratio (CNR) of the ...
M, Petersilka +3 more
openaire +4 more sources
The utilization of dual source CT in imaging of polytrauma
European Journal of Radiology, 2008Despite the growing role of imaging, trauma remains the leading cause of death in people below the age of 45 years in the western industrialized countries. Trauma has been touted as the largest epidemic in the 20th century. The advent of MDCT has been the greatest advance in trauma care in the last 25 years.
S, Nicolaou +6 more
openaire +2 more sources
Thoracic applications of dual-source CT technology
European Journal of Radiology, 2008Among the various imaging modalities available, CT has remained over time the core imaging technique for the evaluation of respiratory disorders. The recent advent of dual-source CT offers innovative approaches to investigate thoracic diseases, based on the use of one or two tubes as well as single or dual energy to scan the entire thorax.
Kahimano, Boroto +8 more
openaire +2 more sources
Persistent truncus arteriosus on dual source CT
Japanese Journal of Radiology, 2016Persistent truncus arteriosus is a rare congenital cardiac disease with variable presentation. The exact preoperative diagnosis and delineation of anatomy are very important because the optimal timing and procedure for truncus arteriosus repair are decided on the basis of the morphological characteristics. Moreover, the presence of associated anomalies
Arun, Sharma, Sarv, Priya, Priya, Jagia
openaire +2 more sources
2010
At the moment, there are two clinical, commercially available Dual Source CT (DSCT) scanners: the SOMATOM Definition and the SOMATOM Definition Flash (both by Siemens AG, Forchheim, Germany). Each of them contains two X-ray tubes and two detectors which are mounted so that the X-ray beams are approximately perpendicular to each other.
Bernhard Krauss +2 more
openaire +1 more source
At the moment, there are two clinical, commercially available Dual Source CT (DSCT) scanners: the SOMATOM Definition and the SOMATOM Definition Flash (both by Siemens AG, Forchheim, Germany). Each of them contains two X-ray tubes and two detectors which are mounted so that the X-ray beams are approximately perpendicular to each other.
Bernhard Krauss +2 more
openaire +1 more source
2008
The introduction of spiral CT in the early 1990s marked one of the important steps in the evolution of CT-imaging techniques.1,2 The technology allowed clinicians for the first time to acquire volume data without the risk of miss- or double-registration.
Bernhard Schmidt +2 more
openaire +1 more source
The introduction of spiral CT in the early 1990s marked one of the important steps in the evolution of CT-imaging techniques.1,2 The technology allowed clinicians for the first time to acquire volume data without the risk of miss- or double-registration.
Bernhard Schmidt +2 more
openaire +1 more source
Dual-source CT cardiac imaging: initial experience
European Radiology, 2006The relation of heart rate and image quality in the depiction of coronary arteries, heart valves and myocardium was assessed on a dual-source computed tomography system (DSCT). Coronary CT angiography was performed on a DSCT (Somatom Definition, Siemens) with high concentration contrast media (Iopromide, Ultravist 370, Schering) in 24 patients with ...
Thorsten R C, Johnson +9 more
openaire +2 more sources
X‐ray scattering in single‐ and dual‐source CT
Medical Physics, 2007For medical imaging applications, such as cardiac imaging, dual‐source computed tomography (CT) improves the temporal resolution by the simultaneous use of two cone beams, which acquire twice as many projections as single‐source CT does within the same time interval.
Klaus J, Engel +2 more
openaire +2 more sources
Helical dual source cone-beam micro-CT
2014 IEEE 11th International Symposium on Biomedical Imaging (ISBI), 2014While helical scanning is well established in the clinical arena, most micro-CT scanners use circular cone beam trajectories and approximate reconstructions based on a filtered backprojection (FBP) algorithm. This may be sufficient for some applications, but in studies of larger animals, such as rats, the size of the detector can constrain the field of
Samuel M. Johnston +2 more
openaire +1 more source
Coronary bifurcation stent morphology in dual-source CT: validation with micro-CT
The International Journal of Cardiovascular Imaging, 2016The aim of this study is to analyze post-bifurcation coronary stent morphology in vitro using dual-source CT and validate those findings using micro-CT. Nine silicon coronary artery phantoms simulating main branch (MB) and side branch (SB) were prepared using a 3-D printer.
Hye-Joung, Eom +8 more