Results 51 to 60 of about 99,070 (255)
Effect of subdural muscle packing in repairing dura mater after retrosigmoid craniotomy
Objective This study was performed to evaluate a new type of autologous muscle tamponade to repair dura mater that has undergone dural defects to prevent cerebrospinal fluid leakage or subcutaneous fluid accumulation.
Hong-an Yang +4 more
doaj +1 more source
We report a multifunctional tapered optical fiber integrating a conformal micro‐resistance temperature detector (µRTD) for local, real‐time thermometry during optical stimulation. The platform combines light‐delivery and temperature sensing within a minimally invasive footprint, enabling detection of sub‐degree cortical heating under representative ...
Antonio Balena +6 more
wiley +1 more source
Dural prostate metastasis presenting as a subdural hematoma
The incidence of subdural hematoma is approximately 13.1/100.000 per year. Subdural hematoma due to skull and dura mater metastases is rare. In this study, a 71-year-old patient with prostate adenocarcinoma who presented with chronic subdural hematoma ...
Mehmet Resid Onen +5 more
doaj +1 more source
The growth and developmental of the myodural bridge and its associated structures in the human fetus
Myodural bridge (MDB) is a dense connective tissue between suboccipital muscle and dura mater. However, there are few reports on the development and maturation of the human MDB.
Yang Song +17 more
doaj +1 more source
Simulated spinal cerebrospinal fluid leak repair: an educational model with didactic and technical components. [PDF]
BACKGROUND: In the era of surgical resident work hour restrictions, the traditional apprenticeship model may provide fewer hours for neurosurgical residents to hone technical skills.
Anderson, Paul A +5 more
core +1 more source
Analysis of current density and related parameters in spinal cord stimulation [PDF]
A volume conductor model of the spinal cord and surrounding anatomical structures is used to calculate current (and current density) charge per pulse, and maximum charge density per pulse at the contact surface of the electrode in the dorsal epidural ...
Boom, Herman B.K. +2 more
core +3 more sources
Non‐Invasive Multidimensional Capacitive Sensing for In Vivo Traumatic Brain Injury Monitoring
Single‐electrode, multidimensional capacitive sensors noninvasively assess cerebral autoregulation and compliance for traumatic brain injury monitoring. ABSTRACT Traumatic brain injury (TBI) is a major cause of death and disability, but invasive intracranial pressure (ICP) monitoring is risky, and current non‐invasive methods lack the resolution and ...
Shawn Kim +8 more
wiley +1 more source
This study employs longitudinal fluorescence imaging in transgenic mice to map post‐craniotomy cortical recovery. We identify distinct neuroimmune recovery phases: microglial structural inflammation peaks at ∼10 days, neuronal structural intensity peaks at ∼14 days and correlates with microglial activity, and functional network modularity is most ...
Guihua Xiao +13 more
wiley +1 more source
Experimental model to study intervertebral disc herniation [PDF]
OBJETIVO: Apresentar um modelo experimental de hérnia de disco e sua validação para estudo da hiperalgesia mecânica e térmica produzidas pelo contato do núcleo pulposo (NP) com as estruturas nervosas envolvidas nessa afecção.
DEFINO, Helton L.A. +3 more
core +2 more sources
Ultrasound Modulation of Visual Circuits in Mice Independent of Auditory Confound
In this study, Qiu et al. found that low‐intensity ultrasound can directly activate sparse ultrasound‐sensitive neurons (UNs) in the primary visual cortex (V1) of deafened mice. The proportion of these sparse UNs is pressure‐dependent. Furthermore, ultrasound modulates visual circuitry with distinct excitatory and inhibitory effects.
Jiaru He +8 more
wiley +1 more source

