The influence of altitude on the differences between Goldmann tonometry and Pascal dynamic contour tonometry: An ecological meta-analysis [PDF]
Purpose: A meta-analysis found that including atmospheric pressure as altitude in generalized linear models reveals higher differences between Goldmann tonometry and Pascal dynamic contour tonometry at higher altitudes, with the difference increasing in ...
Oscar Albis-Donado+3 more
doaj +4 more sources
Comparison between dynamic contour tonometry and Goldmann applanation tonometry correcting equations [PDF]
In order to investigate the reliability of correcting GAT formulas in comparison with dynamic contour tonometry (DCT), this study included 112 right eyes of 112 healthy subjects aged from 21 to 77 years, whose eyes underwent to a full ophthalmologic exam.
Maddalena De Bernardo+5 more
doaj +5 more sources
The Effect of Corneal Thickness, Densitometry and Curvature on Intraocular Pressure Measurements Obtained by Applanation, Rebound and Dynamic Contour Tonometry [PDF]
Evaluate the effect of corneal thickness, densitometry and curvature on intraocular pressure (IOP) measurements obtained by Goldmann applanation tonometry (GAT), non-contact tonometry (NCT), rebound tonometry (RT), and dynamic contour tonometry (DCT).
Marco Antonio de Castro Olyntho Junior+3 more
doaj +5 more sources
Accuracy of dynamic contour tonometry, Goldmann applanation tonometry, and Tono-Pen XL in edematous corneas [PDF]
Purpose: To investigate in vitro the accuracy of dynamic contour tonometry, Goldmann applanation tonometry, and Tono-Pen XL in edematous corneas. Methods: Experimental study included 20 freshly enucleated porcine eyes.
George A. Kontadakis+5 more
doaj +5 more sources
Dynamic contour tonometry over silicone hydrogel contact lens [PDF]
Purpose: This study compared the measurements of intraocular pressure (IOP) and ocular pulse amplitude (OPA) using the Dynamic Contour Tonometry (DCT) over silicone hydrogel contact lenses of different modulus.
Andrew K.C. Lam, Jimmy S.H. Tse
doaj +4 more sources
Evaluation of Goldmann applanation tonometry, rebound tonometry and dynamic contour tonometry in keratoconus [PDF]
Maddalena De Bernardo, Nicola Rosa
doaj +4 more sources
[This corrects the article DOI: 10.4103/0301-4738.171956.].
doaj +4 more sources
Reply to comment by De Bernardo and Rosa on “Evaluation of Goldmann applanation tonometry, rebound tonometry and dynamic contour tonometry in keratoconus” [PDF]
Fatih Özcura, Nilgün Yıldırım
doaj +4 more sources
Objective: To study the correlation and effect of sequential measurement of intraocular pressure (IOP) with Goldmann applanation tonometer (GAT), ocular response analyzer (ORA), dynamic contour tonometer (DCT), and Corvis ST.
Sushma Tejwani+4 more
doaj +4 more sources
Correlation Between Dynamic Contour Tonometry, Uncorrected and Corrected Goldmann Applanation Tonometry, and Stage of Glaucoma. [PDF]
Importance Accurate determination of intraocular pressure (IOP) is crucial for the diagnosis and management of glaucoma. Objective clinical evaluation of the correction equations for Goldmann applanation tonometry (GAT) is lacking.
Wachtl J+4 more
europepmc +3 more sources