Results 21 to 30 of about 409,668 (187)

Intraocular pressure measurements with Goldmann applanation tonometry and dynamic contour tonometry in eyes after IntraLASIK or LASEK [PDF]

open access: goldClinical Ophthalmology, 2012
Gabi Shemesh,* Uri Soiberman,* Shimon KurtzDepartment of Ophthalmology, Tel Aviv Medical Center, and Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel*These two authors contributed equally to this workBackground and methods: Myopic ...
Shemesh G, Soiberman U, Kurtz S
doaj   +4 more sources

Comparison of Goldmann applanation, non-contact, dynamic contour and tonopen tonometry measurements in healthy and glaucomatous eyes, and effect of central corneal thickness on the measurement results [PDF]

open access: goldMedicinski Glasnik, 2018
Aim To compare the correlation of intraocular pressure (IOP) measurements obtained using Goldmann applanation tonometry (GAT), non-contact tonometry (NCT), dynamic contour tonometer (DCT) and tono-pen (TP) in glaucomatous and healthy eyes, and to ...
Aydın Yildiz, Tekin Yasar
doaj   +3 more sources

[Intraocular pressure elevation after vitrectomy-Goldmann applanation tonometry measures lower intraocular pressure than dynamic contour tonometry]. [PDF]

open access: yesOphthalmologe, 2022
BACKGROUND The dynamic contour tonometer PASCAL (DCT) is a direct noninvasive digital tonometer matching the corneal contour. We compared the DCT with the Goldmann applanation tonometer (GAT).
Bäurle S   +3 more
europepmc   +2 more sources

Ocular pulse amplitude in different types of glaucoma using dynamic contour tonometry: Diagnosis and follow-up of glaucoma. [PDF]

open access: yesExp Ther Med, 2017
The aim of the present study was to compare the ocular pulse amplitude (OPA) in patients with different types of glaucoma using dynamic contour tonometry (DCT), to evaluate ocular and systemic factors associated with the OPA and to verify whether OPA ...
Cheng L, Ding Y, Duan X, Wu Z.
europepmc   +2 more sources

Dependence of dynamic contour and Goldmann applanation tonometries on peripheral corneal thickness [PDF]

open access: goldInternational Journal of Ophthalmology, 2017
AIM: To determine the effects of peripheral corneal thickness (PCT) on dynamic contour tonometry(DCT) and Goldmann applanation tonometry (GAT). METHODS: A cross-sectional study.
Federico Saenz-Frances   +8 more
doaj   +2 more sources

The impact of central corneal thickness on values of intraocular pressure measured using two methods: Goldmann applanation and dynamic contour tonometry in patients with open-angle glaucoma [PDF]

open access: yesHalo 194, 2020
Introduction Dynamic contour tonometry (DCT) is a contact, non-applanation method for measuring intraocular pressure (IOP). Objektive The study aimed at evaluating the impact of central corneal thickness (CCT) on values of IOP measured using two methods:
Jordanova Elena   +5 more
doaj   +2 more sources

Effects of Acute Atmospheric Pressure Changes on Dynamic Contour Tonometry and Goldmann Applanation Tonometry in Normal Individuals: A Pilot Study [PDF]

open access: greenJournal of glaucoma, 2020
Précis: Intraocular pressure (IOP) measurement differences with Goldmann applanation tonometry (GAT) and dynamic contour tonometry (DCT) are affected by atmospheric pressure inside a hyperbaric chamber.
Oscar Albis-Donado   +7 more
openalex   +2 more sources

Dynamic contour tonometry and goldman applanation tonometry in eyes with keratoconus Tonometria de contorno dinâmico e tonometria de aplanação de goldman em olhos com ceratocone

open access: goldClinics, 2006
PURPOSE: The dynamic contour tonometer is a nonapplanation contact tonometer designed to be largely independent of the structural properties of the cornea.
Jackson Barreto Jr   +3 more
doaj   +2 more sources

Comparison of IOP obtained in different kind of eyes with contact and no contact tonometers

open access: yesOman Journal of Ophthalmology, 2022
BACKGROUND: The aim of this study is to analyze and compare the intraocular pressure (IOP) values measured in three different kinds of participants such as healthy subjects (HS), keratoconus patients (KP), and those who underwent myopic photorefractive ...
Sandro Sbordone   +6 more
doaj   +2 more sources

Ocular Pulse Amplitude in Non-Diabetic Patients with End Stage Renal Disease and Normal Individuals Using Dynamic Contour Tonometry

open access: diamondNepalese Journal of Ophthalmology, 2019
INTRODUCTION Ocular Pulse Amplitude (OPA) is the fluctuation of IOP with the cardiac cycle which is equal to the difference between systolic and diastolic IOP.
C P Shimna   +4 more
openalex   +3 more sources