Results 111 to 120 of about 6,009,595 (149)

Impact of enhanced leaf model on dose calculation accuracy in single‐isocenter multitarget stereotactic radiosurgery treatments

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose Single‐isocenter multitarget (SIMT) radiosurgery has become increasingly popular as advancement in planning and delivery systems have made this approach clinically viable. With targets varying in size and distance from isocenter, SIMT plans are highly complex with dynamic multileaf collimator (MLC) motion.
Hem Moktan   +3 more
wiley   +1 more source

Commissioning of Halcyon enhanced leaf model in the Eclipse treatment planning system: Focus on simple slit fields and VMAT dose calculation

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose The dual‐layer multileaf collimator (MLC) in Halcyon adds complexities to the dose calculation process owing to the variability of dosimetric characteristics with leaf motion. Recently, an enhanced leaf model (ELM) was developed to refine the MLC model in the Eclipse treatment planning system. This study investigates the performance of
Ryohei Miyasaka   +6 more
wiley   +1 more source

Toward a human‐centric co‐design methodology for AI detection of differences between planned and delivered dose in radiotherapy

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Introduction Many artificial intelligence (AI) solutions have been proposed to enhance the radiotherapy (RT) workflow, but limited applications have been implemented to date, suggesting an implementation gap. One contributing factor to this gap is a misalignment between AI systems and their users.
Luca M. Heising   +11 more
wiley   +1 more source

Quantification and dosimetric impact of intra‐fractional bladder changes during CBCT‐guided online adaptive radiotherapy for pelvic cancer treatments

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose This study quantitatively evaluates bladder changes and their dosimetric impact during the on‐couch adaptive process on a commercial CBCT‐based online adaptive radiotherapy (CT‐gART) platform. Methods Data from 183 fractions of ten patients receiving online ART for pelvic cancers were analyzed retrospectively.
Ingrid Valencia Lozano   +7 more
wiley   +1 more source

Design and validation of a novel dosimetry phantom for motion management audits

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Background We present a novel phantom design for conducting end‐to‐end dosimetry audits for respiratory motion management of two anatomical treatment sites. The design enables radiochromic film measurements of the dose administered to the target throughout the respiratory cycle (motion‐included) and the dose delivered to the time‐averaged ...
Alex Burton   +5 more
wiley   +1 more source

Improving dose delivery in non‐coplanar cranial SRS: Stereoscopic x‐ray‐guided mitigation of table walkout errors

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Purpose Linear accelerator (LINAC)‐based single‐isocenter multi‐target (SIMT) treatment has streamlined the cranial stereotactic radiosurgery (SRS) workflow. Though efficient, SIMT delivery adds additional challenges that should be considered, including increased sensitivity to rotational errors for off‐isocenter targets.
Yohan A. Walter   +4 more
wiley   +1 more source

An investigation into the feasibility and efficacy of stereotactic radiosurgery for 1–3 cm single brain lesions on the ring‐mounted Halcyon LINAC

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose An evaluation of the accuracy, safety, and efficiency of the Halcyon ring delivery system (RDS) for stereotactic radiosurgery (SRS) treatment to relatively small (1–3 cm) brain lesions. Methods After completing the extensive in‐house quality assurance checks including Winston–Lutz test and independent dose verification via MD Anderson ...
Kate Hazelwood   +5 more
wiley   +1 more source

JACMP 2025–2029 and beyond

open access: yes
Journal of Applied Clinical Medical Physics, EarlyView.
Michael Mills
wiley   +1 more source

UR‐cycleGAN: Denoising full‐body low‐dose PET images using cycle‐consistent Generative Adversarial Networks

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose This study aims to develop a CycleGAN based denoising model to enhance the quality of low‐dose PET (LDPET) images, making them as close as possible to standard‐dose PET (SDPET) images. Methods Using a Philips Vereos PET/CT system, whole‐body PET images of fluorine‐18 fluorodeoxyglucose (18F‐FDG) were acquired from 37 patients to ...
Yang Liu, ZhiWu Sun, HaoJia Liu
wiley   +1 more source

Empowering young minds through STEM education: Engaging high schoolers in Ghana through medical physics

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose To promote diversity in Science, Technology, Engineering, and Mathematics (STEM), an educational presentation and hands‐on session was organised to raise awareness of STEM career opportunities among high school girls to introduce the students to the field of medical physics. Materials and Methods The study involved 65 first‐year Senior
Afua A. Yorke   +7 more
wiley   +1 more source

Home - About - Disclaimer - Privacy