Results 91 to 100 of about 9,178 (186)

Role of Hepatitis B Surface Antigen Neutralization Test in Screening of Hepatitis B

open access: yesRGUHS Journal of Allied Health Sciences
Background Hepatitis B caused by hepatitis B virus HBV is a major global health concern. It can be transmitted through parenteral sexual and vertical routes and may lead to severe liver
Kavitha Prabhu   +4 more
doaj   +1 more source

AMH estimation: a comparison between ELISA and ECLIA [PDF]

open access: yesFertility and Sterility, 2018
R. Shankar, S. Mummadi, A. Yerram
openaire   +1 more source

Usporedivost ECLIA i CMIA metode za određivanje koncentracije korionskog gonadotropina

open access: yes, 2016
Uvod: Korionski gonadotropin (CG) koristi se u svrhu rane dijagnoze i praćenja trudnoće te kao tumorski biljeg karcinoma testisa. Objektivnu ocjenu kvalitete metode unutar postavljenih kriterija prihvatljivosti, kao i usporedbu izvedbe različitih metoda omogućuje sustav kvalitete Six Sigma. Cilj: Odrediti Six Sigma vrijednosti ECLIA (engl.
Njire Bratičević, Marina   +3 more
openaire   +2 more sources

The diagnostic value of GICA used for intraoperative lymph node FNA-Tg measurement to evaluate thyroid cancer metastases

open access: yesEuropean Thyroid Journal
Objective: It is crucial to diagnose lymph node (LN) metastases (LNM) before or during thyroid carcinoma surgery. Measurement of thyroglobulin (Tg) in the fine needle aspirate washout (FNA-Tg) is useful to assist in the diagnosis of LNM for papillary ...
Shaodong Hou   +10 more
doaj   +1 more source

Верификација и поређење CLIA са ECLIA имунохемијском методом за одређивање прокалцитонина

open access: yes, 2021
Introduction: Verification of clinical laboratory assays is of great importance in providing evidence to support the manufacturer’s claims that the assay characteristics can be successfully reproduced in the laboratory where the assay will be routinely used.
Bondokić, Kristina, Pešić, Jovana
openaire   +1 more source

Anti-streptavidin antibodies mimicking heterophilic antibodies in thyroid function tests.

open access: yes, 2018
To the Editor, Hereby we report a rare interference that affected the thyroid function tests in two patients seen in our outpatient clinic between May and June 2017.
Favresse, Julien   +11 more
core   +1 more source

AVALIAÇÃO DA CONCORDÂNCIA ENTRE TESTES DE TRIAGEM E COMPLEMENTARES PARA ADOÇÃO DE PROCEDIMENTOS DE RETROVIGILÂNCIA

open access: yesHematology, Transfusion and Cell Therapy
Objetivo: Segundo a Portaria de Consolidação nº5/2017, os serviços de hemoterapia devem adotar procedimentos de retrovigilância quando a triagem sorológica em um doador de sangue, com sorologia negativa em doações prévias, for reagente (positivo ou ...
RC Saez   +6 more
doaj   +1 more source

Limitations of Rapid Test in Early HIV Detection: Comparison with ECLIA Method in Donor Samples

open access: yesNusantara Sehat: Jurnal Kesehatan Indonesia
Background: Blood transfusion safety depends on the ability of screening methods to detect transfusion-transmitted infections (TTIs), including human immunodeficiency virus (HIV). Rapid tests are widely used because they are practical and economical; however, they have limitations in detecting HIV infection during the early stage due to the window ...
null Resmi Aini, null Adira Padmarini
openaire   +1 more source

Evaluation of Fully Automated Electrochemiluminescence Immunoassay for Rapid Detection of Hepatitis B surface antigen and antibodies to Hepatitis C Virus

open access: yesJournal of High Institute of Public Health, 2009
Background: Hepatitis B virus (HBV) and hepatitis C virus (HCV) infections are important global public health problems. The earliest antibody to hepatitis C virus (anti-HCV) and hepatitis B surface antigen (HBsAg) assays had important limitations ...
Ola Wasfi, Nehad Mahdy
doaj   +1 more source

Home - About - Disclaimer - Privacy