Results 71 to 80 of about 9,178 (186)

Usporedba CMIA i ECLIA metode za određivanje koncentracije ciklosporina [PDF]

open access: yes, 2015
Uvod: Ciklosporin A (CSA) je imunosupresiv, ciklički peptid fungalnog porijekla, inhibitor je kalcineurina koji blokira aktivaciju i proliferaciju T-stanica sprječavajući otpuštanje interleukina-2. Praćenje koncentacije (TDM) ciklosporina u transplantiranih bolesnika važno je zbog njegove uske terapijske širine i značajne biološke varijabilnosti ...
Ščavničar, Andrijana   +3 more
openaire   +2 more sources

sGC stimulator BAY 41‐8543 improves survival and ventricular function in a rat model of doxorubicin‐induced cardiomyopathy with nephrotic syndrome

open access: yesBritish Journal of Pharmacology, EarlyView.
Abstract Background and Purpose Anthracyclines such as doxorubicin (DOXO) remain a cornerstone of cancer therapy but are associated with a high risk of cardiotoxicity and subsequent heart failure (HF). Impairment of NO/soluble guanylyl cyclase (sGC)/cGMP pathway has been reported in anthracycline‐induced cardiomyopathy.
Olga Gawrys   +14 more
wiley   +1 more source

The low fasting serum C‐peptide level was associated with reduced sural nerve action potential amplitudes: A cross‐sectional study of Japanese type 2 diabetes

open access: yesJournal of Diabetes Investigation, EarlyView.
Low fasting serum C‐peptide levels were independently associated with abnormal sural nerve action potential amplitude measured by DPNCheck® in patients with type 2 diabetes. Fasting serum C‐peptide may serve as a clinically relevant marker for diabetic polyneuropathy. ABSTRACT Aims/Introduction The association between the fasting serum C‐peptide levels
Taichi Muramatsu   +3 more
wiley   +1 more source

Between-day imprecision (n = 20) of C-peptide, PI and PI:C, determined separately with two automated methods (ECLIA and TRFIA) or simultaneously with the automated TT-TRFIA in pooled human plasma.

open access: yes, 2016
Between-day imprecision (n = 20) of C-peptide, PI and PI:C, determined separately with two automated methods (ECLIA and TRFIA) or simultaneously with the automated TT-TRFIA in pooled human plasma.
Ilse Vermeulen (3373907)   +13 more
core   +1 more source

Evaluation of the Elecsys Syphilis electrochemiluminescence immunoassay as a first-line screening test in the reverse algorithms for syphilis serodiagnosis

open access: yesInternational Journal of Infectious Diseases, 2019
Objectives: With the development of the automated treponemal test, new syphilis serodiagnosis algorithms, reverse algorithm, and European Centre for Disease Prevention and Control (ECDC) algorithm have been recommended recently.
Seungjun Lee   +5 more
doaj   +1 more source

Mapping syphilis surveillance: Insights into blood donation screening practices worldwide

open access: yesVox Sanguinis, EarlyView.
Abstract Background and Objectives Syphilis is caused by the bacterial spirochete Treponema pallidum and can be transmitted through blood transfusion. However, there have been less than 10 documented transfusion‐transmitted cases since World War II.
Michel‐Andrés García‐Otálora   +4 more
wiley   +1 more source

Racial Variations in PSA and PSA Density Among Men With Negative Prostate Biopsies: A Multicenter Comparative Study of Chinese, African American, and Caucasian American Populations

open access: yesCancer Medicine, Volume 15, Issue 11, November 2026.
ABSTRACT Background Prostate‐specific antigen (PSA) and PSA density (PSAD) are widely used for prostate cancer (PCa) screening, but their diagnostic thresholds have not been differentially adjusted for ethnic groups in clinical practice. This multicenter study aimed to establish the distribution of PSA and PSAD in Chinese men without PCa and compare ...
Zhi Xiong   +5 more
wiley   +1 more source

Comparison of chemiluminescence enzyme immunoassay based on magnetic microparticles with traditional colorimetric ELISA for the detection of serum α-fetoprotein

open access: yesJournal of Pharmaceutical Analysis, 2012
A chemiluminescence enzyme immunoassay based on magnetic microparticles (MmPs-CLEIA) was developed to evaluate serum α-fetoprotein (AFP) in parallel with traditional colorimetric enzyme-linked immunosorbent assay (ELISA). A systematic comparison between
Qian-Yun Zhang   +3 more
doaj   +1 more source

Marked Hypergastrinemia and Extreme Erythrocyte Sedimentation Rate Elevation in Autoimmune Atrophic Gastritis with Severe Iron Deficiency Anemia: A Case Report

open access: yesClinical Case Reports, Volume 14, Issue 11, November 2026.
ABSTRACT Autoimmune atrophic gastritis causes loss of oxyntic glands, reduced acid secretion, compensatory hypergastrinemia, and impaired iron and vitamin B12 absorption. A 46‐year‐old woman with minimal gastrointestinal symptoms had fasting serum gastrin > 1800 ng/L, an erythrocyte sedimentation rate of 109 mm/h, hemoglobin 8.2 g/dL, and microcytosis.
Hatem Mousa Taha, Khaled Hatem Taha
wiley   +1 more source

Diagnostic Performance of Three Serological Assays for Anti-SARS-CoV-2 Antibody Detection

open access: yes, 2021
: Objective: To evaluate the diagnostic performance of Electrochemiluminescence (ECLIA) enzyme linked immunosorbent (ELISA) and lateral flow Immunofluorescence (LFIA) for anti-SARS-COV-2 antibody detection.
Dildar, Shabnam   +4 more
core  

Home - About - Disclaimer - Privacy