Analytical validation of anti-toxoplasma IgG immunoassays
There are often discrepancies when using different methods to measure anti-Toxoplasma gondii IgG levels in patient samples. The diagnostic performance of a chemiluminescent immunoassay (CLIA) and an enzyme-linked fluorescent assay (ELFA) used as ...
Guenael Freire de Souza +4 more
doaj +5 more sources
The performance of a laboratory-developed IgG/IgA flow cytometry-based immunoassay (FCI) using Jurkat T cells stably expressing full-length native S protein was compared against Elecsys electrochemiluminiscent (ECLIA) Anti-SARS-CoV-2 S (Roche Diagnostics,
Arantxa Valdivia +7 more
doaj +1 more source
Vaccination against COVID-19 is the main public health approach to fight against the pandemic. The Spike (S) glycoprotein of SARS-CoV-2 is the principal target of the neutralizing humoral response. We evaluated the analytical and clinical performances of
Lina Mouna +4 more
doaj +1 more source
In the spring of 2022, SARS-CoV-2 Omicron BA.2 peaked in Germany. The main burden was staff shortage. To achieve effective identification and management of infected persons as well as early reintegration of recovered persons, an infection-control ...
Rauschning, Dominic +10 more
doaj +1 more source
Performance of LFA and ECLIA in detecting anti-SARS-CoV-2 antibodies.
Anti-SARS-CoV-2 IgM (A) and IgG (B) antibodies were detected using a lateral flow immunochromatographic assay (LFA), and anti-SARS-CoV-2 total antibodies were detected using an electrochemiluminescence immunoassay (ECLIA).
Hiroo Hasegawa (3586247) +16 more
core +1 more source
While lateral flow test formats can be utilized with whole blood and low sample volumes, their diagnostic characteristics are inferior to immunoassays based on chemiluminescence immunoassay (CLIA) or enzyme-linked immunosorbent assay (ELISA) technology ...
Thomas Bodmer +43 more
core +1 more source
Background: Previous studies have indicated the utility of the ADAM10-generated fragment of tau, Tau-A, as marker of neuronal damage. However, the sensitivity of the ELISA-based system was limited.
Tzara, Ourania +13 more
core +1 more source
Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is the virus associated with coronavirus disease (COVID-19). At the time of the study, little data on the level of exposure of the population in Koutiala district in Mali to SARS-CoV-2 was ...
Fara Wagbo Temessadouno +15 more
doaj +2 more sources
Systematic investigation of antibody orientation strategies in lateral flow immunoassays reveals that a para‐substituted (aminomethyl)phenylboronic acid mediated probe (P‐6) combined with a biotin‐streptavidin test‐line modification achieves a synergistic 14‐ to 19‐fold sensitivity gain over conventional conjugation. Furthermore, multiplexed detection,
Pin‐Hao Wang +5 more
wiley +1 more source
Comparison of CBA, MSD ECLIA and SIMOA methods using lysate samples.
The techniques were compared two by two, and slopes and y-intercepts (including 95% CI) were computed for GAD65 values 2 = 0.998. (B) CBA/SIMOA: slope (95%CI) = 0.94 (0.90–0.99); y-intercept (95%CI) = -1.81 (-6.51–2.88) ng/dL; R2 = 0.997.
Sarah Roels (4518385) +7 more