Results 41 to 50 of about 9,178 (186)

Analytical validation of anti-toxoplasma IgG immunoassays

open access: yesBrazilian Journal of Infectious Diseases, 2012
There are often discrepancies when using different methods to measure anti-Toxoplasma gondii IgG levels in patient samples. The diagnostic performance of a chemiluminescent immunoassay (CLIA) and an enzyme-linked fluorescent assay (ELFA) used as ...
Guenael Freire de Souza   +4 more
doaj   +5 more sources

Performance of a flow cytometry-based immunoassay for detection of antibodies binding to SARS-CoV-2 spike protein

open access: yesScientific Reports, 2022
The performance of a laboratory-developed IgG/IgA flow cytometry-based immunoassay (FCI) using Jurkat T cells stably expressing full-length native S protein was compared against Elecsys electrochemiluminiscent (ECLIA) Anti-SARS-CoV-2 S (Roche Diagnostics,
Arantxa Valdivia   +7 more
doaj   +1 more source

Validation of a SARS-CoV-2 Surrogate Virus Neutralization Test in Recovered and Vaccinated Healthcare Workers

open access: yesViruses, 2023
Vaccination against COVID-19 is the main public health approach to fight against the pandemic. The Spike (S) glycoprotein of SARS-CoV-2 is the principal target of the neutralizing humoral response. We evaluated the analytical and clinical performances of
Lina Mouna   +4 more
doaj   +1 more source

Clinical and molecular fingerprint of SARS-CoV-2 among hospital employees in a period of Omicron BA.2 dominance

open access: yesGMS Hygiene and Infection Control
In the spring of 2022, SARS-CoV-2 Omicron BA.2 peaked in Germany. The main burden was staff shortage. To achieve effective identification and management of infected persons as well as early reintegration of recovered persons, an infection-control ...
Rauschning, Dominic   +10 more
doaj   +1 more source

Performance of LFA and ECLIA in detecting anti-SARS-CoV-2 antibodies.

open access: yes, 2021
Anti-SARS-CoV-2 IgM (A) and IgG (B) antibodies were detected using a lateral flow immunochromatographic assay (LFA), and anti-SARS-CoV-2 total antibodies were detected using an electrochemiluminescence immunoassay (ECLIA).
Hiroo Hasegawa (3586247)   +16 more
core   +1 more source

EDTA-Anticoagulated Whole Blood for SARS-CoV-2 Antibody Testing by Electrochemiluminescence Immunoassay (ECLIA) and Enzyme-Linked Immunosorbent Assay (ELISA)

open access: yes, 2020
While lateral flow test formats can be utilized with whole blood and low sample volumes, their diagnostic characteristics are inferior to immunoassays based on chemiluminescence immunoassay (CLIA) or enzyme-linked immunosorbent assay (ELISA) technology ...
Thomas Bodmer   +43 more
core   +1 more source

Quantification of Tau-A in serum after brain injury: a comparison of two analytical platforms, ELISA and electrochemiluminescence immunoassay

open access: yes, 2022
Background: Previous studies have indicated the utility of the ADAM10-generated fragment of tau, Tau-A, as marker of neuronal damage. However, the sensitivity of the ELISA-based system was limited.
Tzara, Ourania   +13 more
core   +1 more source

Seroprevalence of anti-SARS-CoV-2 antibodies among blood donors from December 2020 to June 2021 in Koutiala district, Mali

open access: yesPLOS Global Public Health, 2023
Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is the virus associated with coronavirus disease (COVID-19). At the time of the study, little data on the level of exposure of the population in Koutiala district in Mali to SARS-CoV-2 was ...
Fara Wagbo Temessadouno   +15 more
doaj   +2 more sources

Rational Control of Antibody Orientation for Enhancing Sensitivity and Specificity in Lateral Flow Immunoassays With Clinical Validation

open access: yesAdvanced Healthcare Materials, EarlyView.
Systematic investigation of antibody orientation strategies in lateral flow immunoassays reveals that a para‐substituted (aminomethyl)phenylboronic acid mediated probe (P‐6) combined with a biotin‐streptavidin test‐line modification achieves a synergistic 14‐ to 19‐fold sensitivity gain over conventional conjugation. Furthermore, multiplexed detection,
Pin‐Hao Wang   +5 more
wiley   +1 more source

Comparison of CBA, MSD ECLIA and SIMOA methods using lysate samples.

open access: yes, 2018
The techniques were compared two by two, and slopes and y-intercepts (including 95% CI) were computed for GAD65 values 2 = 0.998. (B) CBA/SIMOA: slope (95%CI) = 0.94 (0.90–0.99); y-intercept (95%CI) = -1.81 (-6.51–2.88) ng/dL; R2 = 0.997.
Sarah Roels (4518385)   +7 more
core   +1 more source