Efficiency calibration of BEGe and extended range detectors
Applied Radiation and Isotopes, 2014Any approach to efficiency calibration of HPGe detectors sensitive to low-energy gamma-rays and X-rays has to deal with true coincidence summing. We developed a method based on the integration of the EFFTRAN code into the commercial Genie2K™ gamma-ray spectrometry software. EFFTRAN's role is to compute true coincidence summing corrections and to obtain
T Vidmar
exaly +4 more sources
Efficiency calibration of HPGe detector in a PGNAA system for the measurement of aqueous samples
Applied Radiation and Isotopes, 2019In this work, a method was proposed for efficiency calibration of HPGe detector employed in a prompt gamma-ray neutron activation analysis (PGNAA) system for large aqueous sample analysis. Experimental measurements of a reference surface gamma-ray source
Wenbao Jia, Daqian Hei, Pingkun Cai
exaly +2 more sources
Efficiency calibration of airborne γ-ray spectrometer using sourceless efficiency calibration method
Journal of Radioanalytical and Nuclear Chemistry, 2019Based on the exponential law of narrow beam γ ray and calculus principle, a numerical calculation model for sourceless efficiency calibration of airborne γ-ray spectrometer has been developed. Through experiments and simulations, it was found that the relative deviation between the efficiency of airborne γ-ray spectrometer with different surface ...
Hexi Wu +4 more
semanticscholar +2 more sources
Angle vs. LabSOCS for HPGe efficiency calibration
Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2019The quantitative determination of radionuclides by gamma ray spectrometry requires a high accuracy of detection efficiency determination. Different software codes for efficiency determination are available.
Ivana Coha +2 more
exaly +2 more sources