Results 241 to 250 of about 6,177,903 (303)
Some of the next articles are maybe not open access.
Applied Radiation and Isotopes, 2023
In this work, a semi-empirical equation in terms of γ-energy, and sample density is derived, proposed, benchmarked, and applied for the peak efficiency calibration of an HPGe detector with respect to an axial source-to-detector configuration. The samples
I. M. Nabil +2 more
semanticscholar +1 more source
In this work, a semi-empirical equation in terms of γ-energy, and sample density is derived, proposed, benchmarked, and applied for the peak efficiency calibration of an HPGe detector with respect to an axial source-to-detector configuration. The samples
I. M. Nabil +2 more
semanticscholar +1 more source
Research on SiPIN Detection Efficiency Calibration
IEEE International Conference on Electronic Measurement & Instruments, 2023In contrast to the traditional experimental approach to detector detection efficiency calibration, the use of a monoenergetic X-ray radiation device for efficiency calibration is the preferred alternative for X-ray detector calibration because of the ...
Shikui Huang +4 more
semanticscholar +1 more source
Applied Radiation and Isotopes, 2022
The general sourceless efficiency calibration has two major methods, Monte Carlo simulation and numerical calculation. Monte Carlo simulation as an important method to address the efficiency calibration in complex measurement systems, despite it being ...
Weicheng Li +6 more
semanticscholar +1 more source
The general sourceless efficiency calibration has two major methods, Monte Carlo simulation and numerical calculation. Monte Carlo simulation as an important method to address the efficiency calibration in complex measurement systems, despite it being ...
Weicheng Li +6 more
semanticscholar +1 more source
Re-construction of a HPGe detector precise modeling for efficiency calibration.
Applied Radiation and Isotopes, 2021High purity germanium (HPGe) detector is a preferred choice for determining the activity of the radioactive samples for nuclear diagnostics of Inertial Confinement Fusion (ICF) experiments.
Changfan Zhang +5 more
semanticscholar +1 more source
Application of a hybrid method for efficiency calibration of a NaI detector.
Applied Radiation and Isotopes, 2021A previously proposed hybrid analytical-numerical method for efficiency calibration of a NaI detector for a point γ-source is extended and applied for other shapes of sources.
K. M. El-Kourghly +5 more
semanticscholar +1 more source
Internal efficiency calibration for bulk samples using a peak-by-peak cascade technique
International Journal of Nuclear Energy Science and Technology, 2016Elsayed K Elmaghraby
exaly +2 more sources
Efficiency calibration of a HPGe detector for the measurement of the primary coolant
Journal of Radioanalytical and Nuclear Chemistry, 2016Qin Guoxiu
exaly +2 more sources
Journal of Radioanalytical and Nuclear Chemistry, 2013
Ivan Sykora, Povinec P P
exaly +2 more sources
Ivan Sykora, Povinec P P
exaly +2 more sources
An Efficient Digitizer for Calibration of Instrument Transformers
2018 IEEE 9th International Workshop on Applied Measurements for Power Systems (AMPS), 2018A new, low cost and efficient digitizer for the calibration of the instrument transformers (IT) is presented in this paper. The proposed digitizer provides digital output directly proportional to ratio and phase errors of the instrument transformer under test, without the need of a separate analog-to-digital converter and signal processor. The existing
Noby George +2 more
openaire +1 more source
An efficient calibration technique for pipeline ADC
2013 IEEE 56th International Midwest Symposium on Circuits and Systems (MWSCAS), 2013Capacitor mismatch and finite op-amp gain are two main error sources for high-resolution pipelined ADCs. This paper presents a high-efficiency digital calibration technique for multi-bit/stage pipeline ADCs. Firstly, capacitor mismatch in multi-bit stage is calibrated in foreground due to its stability to environment.
Chenchen Zhao +3 more
openaire +1 more source