Results 151 to 160 of about 6,977,112 (183)
Some of the next articles are maybe not open access.

Evaluation of the electrical impedance spectroscopy (EIS) equipment for ham meat quality selection

Meat Science, 2001
The objective of this study was to evaluate the electrical impedance spectroscopy (EIS) prototype, to select the hams on the basis of meat quality characteristics in commercial conditions. Measurements of meat quality were made on 95 commercial hams (11.10±0.76 kg) to evaluate quality characteristics [ham weight, conformation (H), fat thickness in the ...
Jacint Arnau
exaly   +3 more sources

Studying the electrical impedance variations in banana ripening using electrical impedance spectroscopy (EIS)

Proceedings of the 2015 Third International Conference on Computer, Communication, Control and Information Technology (C3IT), 2015
Electrical Impedance of biological tissues changes with the change in tissue anatomy and tissue physiology. Electrical Impedance Spectroscopy (EIS) has been studied to characterize the biological objects like fruits and vegetables for assessing their freshness.
Tarun Kumar Bera, Dibyendu Ghoshal
exaly   +2 more sources

Green hams electrical impedance spectroscopy (EIS) measures and pastiness prediction of dry cured hams

Meat Science, 2004
The objective of this study was to assess the value of electrical impedance spectroscopy (EIS) as a predictor of certain dry-cured ham sensory properties in green hams of different technological meat qualities and processed commercially. Measurements of technological meat quality (weight, ham conformation, subcutaneous fat thickness, pH(45) and pH(u ...
Luis Guerrero, Jacint Arnau
exaly   +3 more sources

Electrical impedance spectroscopy (EIS)-based evaluation of biological tissue phantoms to study multifrequency electrical impedance tomography (Mf-EIT) systems

Journal of Visualization, 2016
Electrical impedance tomography (EIT) phantoms are essential for the calibration, comparison and evaluation of the EIT systems. In EIT, the practical phantoms are typically developed based on inhomogeneities surrounded by a homogeneous background to simulate a suitable conductivity contrast.
Tushar Kanti Bera   +2 more
exaly   +4 more sources

Current source enhancements in Electrical Impedance Spectroscopy (EIS) to cancel unwanted capacitive effects

Proceedings of SPIE, 2017
Electrical Impedance Spectroscopy (EIS) has emerged as a non-invasive imaging modality to detect and quantify functional or electrical properties related to the suspicious tumors in cancer screening, diagnosis and prognosis assessment. A constraint on EIS systems is that the current excitation system suffers from the effects of stray capacitance having
C R Chatwin   +2 more
exaly   +2 more sources

Study of stilbene and resin acid content of Scots pine heartwood by electrical impedance spectroscopy (EIS)

Holzforschung, 2011
Abstract Scots pine (Pinus sylvestris L.) heartwood samples were measured with electrical impedance spectroscopy (EIS) at frequency range 1 Hz–10 MHz in green and relative humidity (RH) 65% conditioned moisture content (MC) after oven-drying.
Anni Harju   +2 more
exaly   +2 more sources

The Shape of Electrical Impedance Spectroscopy (EIS) is altered in Stroke Patients

The 26th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, 2005
The shape of the Power Spectral Density Function (PSD) of the Electrical Field Distribution exhibit abnormalities in the brain structure when comparing chronic stroke patients with healthy volunteers. We built a System that can deliver White Noise currents in the 0-25kHz band to any electrode pair.
Giorgio, Bonmassar, Sunao, Iwaki
openaire   +2 more sources

An Investigation into the Electrical Properties of Doped Barium Titanate Using Electrical Impedance Spectroscopy (EIS)

Ferroelectrics, 2013
Barium titanate has been doped with rare earth oxides (erbium, holmium, gadolinium and yttrium), in an attempt to understand the effect upon the reliability of the dielectric material for multilayer capacitor applications. The morphology of the samples used was characterized using scanning electron microscopy (SEM).
Graham Dale   +3 more
openaire   +1 more source

In vivo Electrical-Impedance Spectroscopy (EIS) Readings in the Human Rectum

2016
Worldwide, colorectal cancer (CRC) is one of the leading causes of morbidity and mortality, ranking third among the most common cancers. Although screening programs are useful in reducing its impact, the screening tools available at present are far from being ideal.
Mulett-Vasquez Edelberto   +4 more
openaire   +1 more source

Home - About - Disclaimer - Privacy