Results 61 to 70 of about 2,397,865 (389)

Interaction of class III cellobiose dehydrogenase with lytic polysaccharide monooxygenase

open access: yesFEBS Open Bio, EarlyView.
The activity of lytic polysaccharide monooxygenase (LPMO) is supported by its auxiliary enzyme cellobiose dehydrogenase (CDH). The catalytic activity of both enzymes is coupled by electron transfer and a cyclic cascade generating substrates for both enzymes – hydrogen peroxide for LPMO and oxidized and non‐oxidized cellobiose and cello‐oligosaccharide ...
Angela Giorgianni   +4 more
wiley   +1 more source

Disposable Injection Molded Conductive Electrodes Modified with Antimony Film for the Electrochemical Determination of Trace Pb(II) and Cd(II)

open access: yesSensors, 2019
This work describes a novel electrochemical sensor fabricated by an injection molding process. This device features a conductive polymer electrode encased in a plastic holder and electroplated in situ with a thin antimony film.
Savvina Christidi   +6 more
doaj   +1 more source

Electrochemical Oxidation of Pb II Using Carbon Electrodes Doped with Nanocellulose-FeOx

open access: yesFibers, 2023
With TEMPO oxidation, it was possible to incorporate iron nanostructures into a cellulose nanofiber matrix. FTIR spectra showed the functional groups present in the films.
Araceli G. Gomez-Rojas   +4 more
doaj   +1 more source

Microfluidic electro‐viscoelastic manipulation of extracellular vesicles

open access: yesFEBS Open Bio, EarlyView.
The electro‐viscoelastic manipulation as a potential method for separation of particles based on size. The particles introduced as a sheath flow migrate to the channel center under the influence of simultaneously applied electric field and pressure driven flow.
Seyedamirhosein Abdorahimzadeh   +7 more
wiley   +1 more source

Li-diffusion accelerates grain growth in intercalation electrodes: a phase-field study

open access: yes, 2018
Grain boundary migration is driven by the boundary's curvature and external loads such as temperature and stress. In intercalation electrodes an additional driving force results from Li-diffusion. That is, Li-intercalation induces volume expansion of the
Balakrishna, Ananya Renuka   +2 more
core   +1 more source

Three-electrode current-voltage measurements on erbia-stabilized bismuth oxide with sputtered noble metal electrodes [PDF]

open access: yes, 1992
The anodic and cathodic polarization behaviour of sputtered porous gold electrodes on (Bi2O3)0.75(Er2O3)0.25 (abbreviated BE25) was studied as function of temperature and oxygen partial pressure using a three-electrode cell.
Boukamp, B.A.   +3 more
core   +3 more sources

On the illumination of electrodes [PDF]

open access: yesThe London, Edinburgh, and Dublin Philosophical Magazine and Journal of Science, 1880
n ...
openaire   +2 more sources

Patient Selection in Deep Brain Stimulation: A Role for Transcranial Direct Current Stimulation to Enhance the Levodopa Challenge?

open access: yesAnnals of Clinical and Translational Neurology, EarlyView.
ABSTRACT Dopaminergic medication and deep brain stimulation (DBS) improve motor symptoms in Parkinson's disease (PD), but levodopa response alone may not predict DBS outcomes. We retrospectively analyzed 19 PD patients undergoing levodopa challenges with and without prior transcranial direct current stimulation targeting a defined PD response network ...
Lukas L. Goede   +3 more
wiley   +1 more source

Crystal structure of poly[aqua-(μ 2-3-bromoisonicotinato-κ 2 N: O)-(μ 2-3-bromoisonicotinato-κ 3 N: O: O′)-(μ 3-3-bromoisonicotinato-κ 3 N: O: O′)-(μ 2-nitrite-κ 3 O: O′: O″)dicadmium(II) monohydrate], C19H12Br3Cd2N3O9

open access: yesZeitschrift für Kristallographie - New Crystal Structures
C19H12Br3Cd2N3O9, triclinic, P 1− $\overset{-}{1}$ (no. 2), a = 8.5783(3) Å, b = 10.1346(3) Å, c = 15.5520(5) Å, α = 85.633(1)∘, β = 89.906(1)∘, γ = 65.269(1)∘, V = 1223.80(7) Å3, Z = 2, R gt(F) = 0.0368, wR ref(F 2) = 0.0935, T = 299 K.
Li Kuan-Ying   +3 more
doaj   +1 more source

Fabrication of Micro-Needle Electrodes for Bio-Signal Recording by a Magnetization-Induced Self-Assembly Method

open access: yesSensors, 2016
Micro-needle electrodes (MEs) have attracted more and more attention for monitoring physiological electrical signals, including electrode-skin interface impedance (EII), electromyography (EMG) and electrocardiography (ECG) recording.
Keyun Chen   +5 more
doaj   +1 more source

Home - About - Disclaimer - Privacy