Results 21 to 30 of about 88 (79)
In recent years, with the rapid development of offshore wind turbines (WTs), the problem of lightning strikes has become more and more prominent. In order to reduce the failure rate caused by the transient overvoltage of lightning struck offshore WTs ...
Li Zhang +4 more
doaj +1 more source
Pemodelan karakteristik arrester pada jaringan transmisi 150kv akibat sambaran petir merupakan salah satu cara yang praktis untuk membentuk jalan yang mudah dilalui oleh arus petir, sehingga tidak timbul tegangan lebih pada peralatan.
Mochammad Apriyadi
doaj +1 more source
The compact design of a 500 kV quadruple-circuit transmission line can effectively reduce the line corridor area, but the height of the tower also increases, increasing the probability of suffering a lightning strike.
Qianxin Zhu +11 more
doaj +1 more source
Smart Grid Resilience for Grid-Connected PV and Protection Systems under Cyber Threats
In recent years, the integration of Distributed Energy Resources (DERs) and communication networks has presented significant challenges to power system control and protection, primarily as a result of the emergence of smart grids and cyber threats.
Feras Alasali +6 more
doaj +1 more source
Systematization of the Simulation Process of Transformer Inrush Current Using EMTP
An inrush current is generated when a transformer is energized. This current has a large magnitude and rich harmonics, thereby causing mal-operation of the protection relay.
Hun-Chul Seo, Gi-Hyeon Gwon
doaj +1 more source
The analysis of lightning overvoltages generated in electrical power systems has a great meaning for the designers and exploitation engineers because it creates bases for the optimization of construction overhead transmission lines and high voltage ...
Jakub Furgał
doaj +1 more source
Evaluation of the Transient Overvoltages of HVDC Transmission Lines Caused by Lightning Strikes
High-voltage direct-current (HVDC) transmission systems are considered an outstanding solution due to high electrical losses emerging from long-distance transmission. However, HVDC transmission lines (TLs) are vulnerable to lightning strikes.
Amr S. Zalhaf +5 more
doaj +1 more source
When a long marshaling high-speed train (HST) with two raised pantographs passes an articulated split-phase region, there will be eight electromagnetic transient processes along with pantograph arcing.
Ke Huang, Zhigang Liu, Xin Li
doaj +1 more source
PC Implementation of a Real-Time Simulator Using ATP Foreign Models and a Sound Card
This work reports the personal computer implementation of a real-time simulator based on the widely used Electromagnetic Transients Program, version Alternative Transients Program (EMTP-ATP) software for testing protection and control devices.
Renzo G. Fabián Espinoza +2 more
doaj +1 more source
Power system protection devices are vulnerable to adversarial samples. We propose a digital twin and reinforcement learning framework. It trains a virtual model within safe operational boundaries, reducing the false operation rate to below 3.5%. The model's inference delay is under 10 ms, meeting real‐time protection requirements.
Wei Zhang +3 more
wiley +1 more source