Design and evaluation of multidimensional CNN simulation framework against synchrophasor data spoofing attacks and correction for cyber‐resiliency in power system

open access: yesIET Generation, Transmission &Distribution, Volume 19, Issue 1, January/December 2025.
The technique involves source authentication to detect anomalies in phasor measurement unit (PMU) data by extracting spatial fingerprint information. The extracted information is then used as inputs for a multi‐dimensional convolutional neural network simulation framework.
Robert Nobili Britto Thomas   +3 more
wiley   +1 more source

A state‐variable‐preserving method for the efficient modelling of inverter‐based resources in parallel EMT simulation

open access: yesIET Generation, Transmission &Distribution, Volume 19, Issue 1, January/December 2025.
This paper proposes a state‐variable‐preserving (SVP) method to achieve efficient modelling of renewable energy power generation units and a node tearing method to realize parallel simulation of the renewable energy power generation station based on the constructed SVP model.
Qiguo Wang   +4 more
wiley   +1 more source

Power Dispatching Method for a De‐Loading Operated Wind Farm Participating in Power System Frequency Regulation Considering Wake Effect

open access: yesIET Renewable Power Generation, Volume 19, Issue 1, January/December 2025.
This paper proposes an optimised power dispatching method for a wind farm (WF) during a de‐loading operation. The WF control centre collects wind speed information of each wind turbine and creates several groups, including wind turbines with similar wind speeds.
Taiying Zheng, Zhaoji Liu
wiley   +1 more source

Study on the Correction Method of Lightning Strike Trip Rate of Transmission Lines Under the Complex Influence of Microtopography Factors

open access: yesIET Science, Measurement &Technology, Volume 19, Issue 1, January/December 2025.
In order to correct the results of the lightning strike trip rate simulation calculations, in this paper, we have completed the automatic identification and extraction of microtopography of transmission line towers in Yunnan area through geographic information software and physical simulation analysis of surface flowing water, and established a BP ...
Jintian Chen   +7 more
wiley   +1 more source

Simulation of a Fixed Pitch Wind Turbine Powered Induction Generator in EMTP

open access: yes, 1994
Simulation of a fixed pitch wind turbine powered induction generator in EMTP Described are two models of a fixed pitch wind turbine drive train coupled to an induction generator compatible with the Electromagnetic Transients Program (EMTP).
C. V. Nayar, J. Perahia
core   +1 more source

An Enhanced Avdonin‐Based Approach With Probabilistic Coefficients for Incipient Fault Modeling in Underground Power Cables

open access: yesInternational Transactions on Electrical Energy Systems, Volume 2025, Issue 1, 2025.
One well‐known fault that arises from water intrusion and power cable insulation failure is the incipient fault (IF) in underground power cables (UPCs). Therefore, it is necessary to provide appropriate models for modeling this fault and also to generate data close to the actual value for validating IF detection methods. This study presents a model for
Zahra Hosseini   +4 more
wiley   +1 more source

Lightning electromagnetic field coupling to overhead lines: Theory, numerical simulations, and experimental validation

open access: yes, 2009
—The evaluation of electromagnetic transients in over-head power lines due to nearby lightning return strokes requires accurate models for the calculation of both the incident lightning electromagnetic pulse (LEMP) and the effects of coupling of this ...
Farhad Rachidi   +21 more
core   +1 more source

Induced Voltages Ratio-Based Algorithm for Fault Detection, and Faulted Phase and Winding Identification of a Three-Winding Power Transformer

open access: yesEnergies, 2014
This paper proposes an algorithm for fault detection, faulted phase and winding identification of a three-winding power transformer based on the induced voltages in the electrical power system.
Byung Eun Lee   +3 more
doaj   +1 more source

Recent Advances in Design of Fault Current Limiters for Modern Power Grid Networks: A Critical Review

open access: yesJournal of Electrical and Computer Engineering, Volume 2025, Issue 1, 2025.
Fault current limiters (FCLs) are essential components in modern power systems for critical protection against the damaging effects of fault currents. With extensive short circuits, routine electrical faults, and an increasing risk of failure due to unprecedented events, the development of different types of FCL has gained attention.
Tamalika Chowdhury   +2 more
wiley   +1 more source

Transient analysis of a distribution transformer using ATP-EMTP

open access: yes, 2018
© 2018 IEEE. The paper reports investigation on different parameters of an 11-kV line that affect the lightning impulse failure of a distribution transformer in Pakistan.
Ali, M, Saqib, MA
core   +1 more source