In order to correct the results of the lightning strike trip rate simulation calculations, in this paper, we have completed the automatic identification and extraction of microtopography of transmission line towers in Yunnan area through geographic information software and physical simulation analysis of surface flowing water, and established a BP ...
Jintian Chen +7 more
wiley +1 more source
Characteristic Test of Current Transformer Based EMTP Shoftware [PDF]
Pemodelan transformator arus merupakan salah satu cara yang praktis untuk mengevaluasi unjuk kerja perlengkapan proteksi. Pada makalah ini disajikan penggunaan perangkat lunak Electromagnetic Transients Program (EMTP), The Output Processor (TOP), dan ...
Syahputra, R. (Ramadoni)
core
Modelling of a 400-kV MSCDN reactor for computation of voltage and field distributions during switching transients [PDF]
In this paper, a model for the reactor of a 400-kV mechanically switched capacitor with damping network (MSCDN) based on an equivalent circuit representation is developed.
Abdul Hamid, Haziah +3 more
core +2 more sources
One well‐known fault that arises from water intrusion and power cable insulation failure is the incipient fault (IF) in underground power cables (UPCs). Therefore, it is necessary to provide appropriate models for modeling this fault and also to generate data close to the actual value for validating IF detection methods. This study presents a model for
Zahra Hosseini +4 more
wiley +1 more source
Profil Surja Hubung Karena Proses Energized Pada Saluran Transmisi 500 Kv [PDF]
Transient over voltage that happened because switching surge have to be paid attention to don\u27t cause the damage equipments of insulation coordination system.
Yuniarto, Y. (Yuniarto)
core
Fault current limiters (FCLs) are essential components in modern power systems for critical protection against the damaging effects of fault currents. With extensive short circuits, routine electrical faults, and an increasing risk of failure due to unprecedented events, the development of different types of FCL has gained attention.
Tamalika Chowdhury +2 more
wiley +1 more source
This paper proposes an algorithm for fault detection, faulted phase and winding identification of a three-winding power transformer based on the induced voltages in the electrical power system.
Byung Eun Lee +3 more
doaj +1 more source
KARAKTERISTIK TEGANGAN LEBIH KONDISI TRANSIENT SAAT PROSES ENERGIZED (PEMBERIAN TENAGA) PADA SALURAN TRANSMISI 500 KV [PDF]
Yuniarto, in paper transient overload characteristic at energized prosses on 500 kv transmission line explain that transient over voltage that happened caused switching surge have to be paid attention to don't cause the damage equipments of insulation ...
Yuniarto, Yuniarto
core
Environmentally friendly compact air-insulated high-voltage substations [PDF]
This paper investigates the possible options for achieving a substantial reduction in a substation footprint using air-insulated switchgear as a more environmentally-friendly alternative to gas-insulated substations that use SF6 gas.
Albano, Maurizio +3 more
core +2 more sources
A full‐size steel‐framed residential test platform was constructed near a 1000‐kV ultra‐high‐voltage AC transmission line, then the performances of transient electric shocks when human bodies contacting a metal clothes hanger were investigated. The transient shock current characteristics and correlation between transient shock energy and human ...
Wangling He +7 more
wiley +1 more source