Effect of microwave power on EPR spectra of natural and synthetic dental biocompatible materials
Paramagnetic centers in the two exemplary synthetic and natural dental biocompatible materials applied in implantology were examined by the use of an X-band (9.3 GHz) electron paramagnetic resonance (EPR) spectroscopy.
Adamczyk Jakub +2 more
doaj +1 more source
Single crystals of α and γ glycine manganese chloride (GMC) were prepared using four dopant concentrations of MnCl2 in the molecular formula (C2H5NO2)1−x(MnCl2)x, where [x = 0.005, 0.02, 0.04, 0.05]. The crystals showed: nonlinear optical (NLO) activity,
Ollaa M. Mailoud +3 more
doaj +1 more source
Characterization of Shewanella oneidensis MtrC: a cell-surface decaheme cytochrome involved in respiratory electron transport to extracellular electron acceptors [PDF]
MtrC is a decaheme c-type cytochrome associated with the outer cell membrane of Fe(III)-respiring species of the Shewanella genus. It is proposed to play a role in anaerobic respiration by mediating electron transfer to extracellular mineral oxides that ...
AI Tsapin +52 more
core +1 more source
High-spin Metal Centres in Dipolar EPR Spectroscopy
The substitution of Mg2+ by Mn2+ in the bacterial DnaB helicase from Helicobacter pylori, an ATP:Mg2+-fuelled protein engine, allows electron paramagnetic resonance (EPR) spectroscopy to be performed on this system.
Katharina Keller +6 more
doaj +1 more source
The intrinsic iron(III) impurity center in polycrystalline lead titanate was investigated by means of high-frequency electron paramagnetic resonance (EPR) spectroscopy in order to determine the local-environment sensitive fine structure parameter D. At a
Brunel, Louis Claude +5 more
core +1 more source
Study of the local field distribution on a single-molecule magnet-by a single paramagnetic crystal; a DPPH crystal on the surface of an Mn12-acetate crystal [PDF]
The local magnetic field distribution on the subsurface of a single-molecule magnet crystal, SMM, above blocking temperature (T >> Tb) detected for a very short time interval (~ 10-10 s), has been investigated.
Boris Rakvin +5 more
core +2 more sources
High Resolution Microimaging with Pulsed Electrically-Detected Magnetic Resonance
The investigation of paramagnetic species (such as point defects, dopants, and impurities) in solid-state electronic devices is significant because of their effect on device performance.
Blank, Aharon +4 more
core +1 more source
Electron paramagnetic resonance and quantitative color investigations of various vacuum heat treated wood species [PDF]
The effect of the heat treatment duration on the electron paramagnetic resonance signal amplitude of free radicals for various wood species was observed.
E.I. Kondratyeva, K.R. Safiullin, I.G. Motygullin, A.V. Klochkov, M.S. Tagirov, V.V. Kuzmin
doaj
Electron paramagnetic resonance study of Eu2+ centers in melt-grown CsBr single crystals [PDF]
The structure of Eu2+ monomer centers in CsBr single crystals is investigated using electron paramagnetic resonance (EPR) spectroscopy. These centers are produced by heating the melt-grown crystals above 600 K in vacuum followed by a rapid quench to room
Callens, Freddy +5 more
core +1 more source
In this work, a magnetic core‐shell catalyst (HOF‐on‐Fe3O4/ZIF‐67) is successfully synthesized, consisting of a metal–organic framework (ZIF‐67) with magnetic Fe3O4 as the core and a porous hydrogen‐bonded organic framework (HOF) as the shell. The catalyst efficiently activated peroxymonosulfate, resulting in rapid and effective removal of water ...
Yingying Du +4 more
wiley +1 more source

