Results 21 to 30 of about 7,705 (226)

The influence of acquisition mode on the dosimetric performance of an amorphous silicon electronic portal imaging device

open access: yesJournal of Medical Physics, 2017
Aims: This study investigates the impact of cine acquisition mode on the dosimetric characteristics of a Varian aS500 amorphous silicon electronic portal imaging device (a-Si EPID).
Omemh Bawazeer   +4 more
doaj   +2 more sources

Electronic Portal Imaging Device (EPID) Portal Image Filtering for Simplifying Registration on Radiation Therapy

open access: yesJapanese Journal of Radiological Technology, 2012
A simple method for improving the quality of electronic portal imaging device (EPID) portal images was proposed for the reduction of the burden on the registration between digital reconstruction radiography (DRR) and EPID portal images in radiation therapy.
Masaki Ohkubo
exaly   +4 more sources

Investigation of the mechanical performance of Siemens linacs components during arc: gantry, MLC, and electronic portal imaging device [PDF]

open access: yesMedical Devices: Evidence and Research, 2015
Pejman Rowshanfarzad,1 Peter Häring,2 Hans L Riis,3 Sune J Zimmermann,3 Martin A Ebert1,4 1School of Physics, The University of Western Australia, Crawley, WA, Australia; 2German Cancer Research Center (DKFZ), Medical Physics in Radiation Oncology ...
Rowshanfarzad P   +4 more
doaj   +2 more sources

Determination of dosimetric leaf gap using amorphous silicon electronic portal imaging device and its influence on intensity modulated radiotherapy dose delivery

open access: yesJournal of Medical Physics, 2015
As complex treatment techniques such as intensity modulated radiotherapy (IMRT) entail the modeling of rounded leaf-end transmission in the treatment planning system, it is important to accurately determine the dosimetric leaf gap (DLG) value for a ...
S Timothy Peace Balasingh   +4 more
doaj   +2 more sources

Clinical performance of FractionLab in patient-specific quality assurance for intensity-modulated radiotherapy: a retrospective study [PDF]

open access: yesJournal of Yeungnam Medical Science, 2022
Background This study was aimed at comparing and analyzing the results of FractionLab (Varian/Mobius Medical System) with those of portal dosimetry that uses an electronic portal imaging device.
Se An Oh   +4 more
doaj   +1 more source

Development of Artificial Intelligence as a Conversion Tool for Cine Electronic Portal Imaging Device Images to Radiotherapy Dosimetry: Preliminary Study [PDF]

open access: yesIranian Journal of Medical Physics, 2022
Introduction: This research is a preliminary study of the development of Artificial Intelligence (AI) as a conversion tool from the pixel value of Cine a-Si 1000 Electronic Portal Imaging Device (EPID) images to dose.
Muhammad Ramadhan   +2 more
doaj   +1 more source

A review of electronic portal imaging devices (EPIDs) [PDF]

open access: yesMedical Physics, 1992
On‐line electronic portal imaging devices are beginning to come into clinical service in support of radiotherapy. A variety of technologies are being explored to provide real‐time or near real‐time images of patient anatomy within x‐ray fields during treatment on linear accelerators.
Boyer, Arthur L.   +7 more
openaire   +4 more sources

The dose response relationship of a liquid-filled electronic portal imaging device [PDF]

open access: yes, 1996
To use a liquid-filled portal imaging device (EPID) for transmission dosimetry, it is necessary to understand its dosimetric properties. Therefore, the relation between the pixel values (i.e., ionization currents) of an electronic portal imaging device ...
Mijnheer, B. J.   +2 more
core   +5 more sources

Evaluation of Patient Set Up Errors in Head and Neck Three-Dimensional (3D) Conformal and Intensity-Modulated Radiotherapy Using Electronic Portal Imaging Device [PDF]

open access: yesIranian Journal of Medical Physics, 2022
Introduction: Interfractional set-up variations may cause deviation of the delivered dose from the planned dose distribution. This study aimed at calculating random and systematic set-up errors using an electronic portal imaging device (EPID) to set the ...
Alireza Farajollahi   +6 more
doaj   +1 more source