Two-dimensional exit dosimetry using a liquid-filled electronic portal imaging device and a convolution model. [PDF]
BACKGROUND AND PURPOSE: To determine the accuracy of two-dimensional exit dose measurements with an electronic portal imaging device, EPID, using a convolution model for a variety of clinically relevant situations.
Mijnheer, B +12 more
core +1 more source
Aim: The Mobius3D software addresses limitations lacking in measurement-based methods in patient-specific quality assurance (QA). The objective of this study was to validate its dosimetric performance against conventionally used portal dose measurements ...
Yasmine Joy M. Labagnoy +3 more
doaj +1 more source
Improvement of radiotherapy treatment delivery accuracy using an electronic portal imaging device [PDF]
Reliable application of advanced external beam techniques for the treatment of patients with cancer, such as intensity modulated radiotherapy, requires an adequate quality assurance programme for the verification of the dose delivery.
Dirkx, M. L.P. +2 more
core +1 more source
The aim of this study was to examine the impact of dose rate on accuracy of intensity modulated radiation therapy (IMRT) plan delivery by comparing the gamma agreement between the calculated and measured portal doses by pretreatment quality assurance (QA)
Karunakaran Kaviarasu +4 more
doaj +1 more source
Purpose: This study aimed to compare thermoplastic mask with bra in terms of setup reproducibility and immobilization of pendulous breasts during radiation therapy (RT).
Zaheeda Mulla, BTech (RT) +5 more
doaj +1 more source
Utilization of Electronic Portal Imaging Device (EPID) For Setup Verification and Determination of Setup Margin in Head and Neck Radiation Therapy [PDF]
Introduction: Radiation therapy involves a multistep procedure; therefore, the error in patient set up is an inherent part of the treatment. Main purpose of this study was to determine the clinical target volume (CTV) to planning target volume (PTV) in ...
vajiheh vejdani noghreiyan +2 more
doaj +1 more source
Daily organ tracking in intensity-modulated radiotherapy of prostate cancer using an electronic portal imaging device with a dose saving acquisition mode [PDF]
BACKGROUND AND PURPOSE: Daily use of conventional electronic portal imaging devices (EPID) for organ tracking is limited due to the relatively high dose required for high quality image acquisition.
Thalmann, Sandrine +7 more
core +1 more source
Spin‐Split Edge States in Metal‐Supported Graphene Nanoislands Obtained by CVD
Combining STM measurements and ab‐initio calculations, we show that zig‐zag edges in graphene nanoislands grown on Ni(111) by CVD retrieve their spin‐polarized edge states after intercalation of a few monolayers of Au. ABSTRACT Spin‐split states localized on zigzag edges have been predicted for different free‐standing graphene nanostructures.
Michele Gastaldo +6 more
wiley +1 more source
Background Set-up errors are an inherent part of radiation treatment process. Coverage of target volume is a direct function of set-up margins, which should be optimized to prevent inadvertent irradiation of adjacent normal tissues. The aim of this study
Devi P Reena +6 more
doaj +1 more source
Dosimetry with a fluoroscopic electronic portal imaging device [PDF]
Techniques for dosimetric verification of radiotherapy treatments using a CCD camera based fluoroscopic electronic portal imaging device (EPID) are described. The dosimetric characteristics of the EPID were investigated and a method was developed to derive portal dose images (PDIs) from measured EPID images.
openaire +1 more source