Evaluation of an Electronic Portal Imaging Device for Transit Dosimetry [PDF]
The possibility of using a commercially available electronic portal imaging device for transit dosimetry was investigated. The detection unit of the device comprises a metal plate/fluorescence screen and a camera. Basic parameters of this system were investigated: stability, detector uniformity, dose-response curve, field-size dependence and phantom ...
X, He +3 more
openaire +2 more sources
Background A novel remote method for external dosimetric TPS-planned auditing of intensity modulated radiotherapy (IMRT) and volumetric modulated arc therapy (VMAT) for clinical trials using electronic portal imaging device (EPID) has been developed. The
Narges Miri +7 more
doaj +1 more source
Objective: This study demonstrates a novel electronic portal imaging device (EPID)-based forward dosimetry approach for pretreatment quality assurance aided by a treatment planning system (TPS).
Arjunan Manikandan +3 more
doaj +1 more source
A High-Throughput In Vitro Radiobiology Platform for Megavoltage Photon Linear Accelerator Studies
We designed and developed a multiwell tissue culture plate irradiation setup, and intensity modulated radiotherapy plans were generated for 96-, 24-, and 6-well tissue culture plates.
Kamalram Thippu Jayaprakash +6 more
doaj +1 more source
Ce doped SiO2 optical fibers for remote radiation sensing and measurement [PDF]
Scintillating materials, able to efficiently operate the conversion of energy absorbed in the form of ionizing radiation into light in the visible UV interval, are presently used in a wide class of applications as medical imaging, industrial inspection ...
Marco Brambilla +38 more
core +1 more source
Commissioning and Evaluation of an Electronic Portal Imaging Device-Based In-Vivo Dosimetry Software. [PDF]
This study reports on our experience with the in-vivo dose verification software, EPIgray® (DOSIsoft, Cachan, France). After the initial commissioning process, clinical experiments on phantom treatments were evaluated to assess the level of accuracy of ...
Held M +4 more
europepmc +4 more sources
Radiotherapy treatment verification using radiological thickness measured with an amorphous silicon electronic portal imaging device: Monte Carlo simulation and experiment [PDF]
This work validates the use of an amorphous-silicon, flat-panel electronic portal imaging device (a-Si EPID) for use as a gauge of patient or phantom radiological thickness, as an alternative to dosimetry.
Fielding, A.L. +5 more
core +1 more source
INTRODUCTION: Dosimetry verification is required before starting each treatment. The legal regulations do not clearly define one method of plan verification.
Adam Gądek +4 more
doaj +1 more source
Two-dimensional exit dosimetry using a liquid-filled electronic portal imaging device and a convolution model. [PDF]
BACKGROUND AND PURPOSE: To determine the accuracy of two-dimensional exit dose measurements with an electronic portal imaging device, EPID, using a convolution model for a variety of clinically relevant situations.
Mijnheer, B +12 more
core +1 more source
Improvement of radiotherapy treatment delivery accuracy using an electronic portal imaging device [PDF]
Reliable application of advanced external beam techniques for the treatment of patients with cancer, such as intensity modulated radiotherapy, requires an adequate quality assurance programme for the verification of the dose delivery.
Dirkx, M. L.P. +2 more
core +1 more source