Results 61 to 70 of about 7,705 (226)
The potential impact of CT-MRI matching on tumor volume delineation in advanced head and neck cancer [PDF]
PURPOSE: To study the potential impact of the combined use of CT and MRI scans on the Gross Tumor Volume (GTV) estimation and interobserver variation.
Touw, A. +35 more
core +1 more source
Task‐adaptive programmable optics enables label‐free virtual staining through optical‐attention‐guided acquisition and reconstruction. By optimizing wavelength, illumination angle, exposure time, and imaging depth, the framework learns task‐relevant optical measurements, generating clinically interpretable virtual stains with improved fidelity, non ...
Tianyue He +13 more
wiley +1 more source
An Empirical Transmitted EPID Dosimetry Method using a Back-Projection Algorithm [PDF]
Background: The present study aimed to introduce a rapid transmission dosimetry through an electronic portal-imaging device (EPID) to achieve two-dimensional (2D) dose distribution for homogenous environments. Material and Methods: In this Phantom study,
S M Hashemi +8 more
doaj +1 more source
Schematic illustration of a biomimetic SKEV@AAV platform targeting p21‐high senescent Kupffer cells (sKCs) in hepatocellular carcinoma (HCC) with portal vein tumor thrombus (PVTT). p21‐high sKCs accumulate in the PVTT microenvironment and establish an immunosuppressive, SASP‐rich environment that facilitates tumor cell proliferation and immune evasion.
Na Ta +10 more
wiley +1 more source
A phantom based evaluation of the clinical imaging performance of electronic portal imaging devices
In this study an evaluation of the imaging performance of an electronic portal imaging device (EPID) is presented. The evaluation performed employing the QC-3V image quality phantom.An EPID system of a 6 MV LINAC, was used to obtain images of a QC-3V EPID phantom. The X-ray source to phantom distance was 100 cm and the field size was 15x15 cm2.
Marios K. Tzomakas +9 more
openaire +4 more sources
A next-generation electronic portal imaging device for simultaneous imaging and dosimetry in radiotherapy [PDF]
The aim of this thesis is to develop a next-generation Electronic Portal Imaging Device (EPID) for simultaneous megavoltage imaging and dosimetry in radiotherapy.
Cheng, Zhangkai Jason
core
Data from: Setup in a clinical workflow and impact on radiotherapy routine of an in vivo dosimetry procedure with an electronic portal imaging device [PDF]
High conformal techniques such as intensity-modulated radiation therapy and volumetric-modulated arc therapy are widely used in overloaded radiotherapy departments.
Kang, Shengwei +9 more
core +1 more source
A Computational Approach for Biomimetic Design of Liver‐On‐A‐Chip
A biomimetic liver‐on‐a‐chip with antiparallel perfusion was designed using COMSOL‐guided simulation to replicate hepatic acinus transport. Full‐scale modelling revealed diffusion‐dominated, length‐dependent nutrient gradients and low‐shear conditions.
Zhenxu Yang +9 more
wiley +1 more source
modern clinical electron linear accelerator was commissioned at the Department of Radiotherapy in the Oncology and Radiobiology Institute. The use of electronic portal image device (EPID) for patient-specific intensity modulated radiotherapy (IMRT ...
Eduardo F. Larrinaga Cortina +1 more
doaj
Transmission dosimetry with a scanning liquid filled electronic portal imaging device for megavoltage photo beams [PDF]
An important question with respect to radiation therapy is to what degree of accuracy, dose delivery can be achieved in clinical practice. It is well understood that accurate delivery of a specific radiation dose to a target volume is critical to the ...
Parsaei, Homayoon
core

