Results 141 to 150 of about 18,365 (214)

Structural Effects of Vertical Non‐Skeletal Elements (NSEs) With Rocking Mechanisms

open access: yesEarthquake Engineering &Structural Dynamics, EarlyView.
ABSTRACT This paper introduces the structural effects provided by vertical non‐skeletal elements (NSEs), such as claddings and partitions, with vertical slotted holes at their supports to enable rocking as the frame undergoes significant lateral deformation.
Zheng Luo   +2 more
wiley   +1 more source

CLEIA-based type IV collagen 7S for second-step assessment of MRE-defined clinically significant fibrosis in MASLD with indeterminate FIB-4. [PDF]

open access: yesSci Rep
Murakami S   +12 more
europepmc   +1 more source

Numerical Simulations of 5‐Story Building Using Wood Light‐Frame Shear Walls and Post‐Tensioned Cross‐Laminated Timber Rocking Wall Dual Systems

open access: yesEarthquake Engineering &Structural Dynamics, EarlyView.
ABSTRACT This study explores the seismic performance of a five‐story prototype building using different configurations of a dual lateral force‐resisting system (LFRS) combining post‐tensioned cross‐laminated timber rocking walls (PT‐CLT‐RW) with conventional wood light‐frame shear walls (LiFS).
Ruben Jerves, Adam R. Phillips
wiley   +1 more source

Comparative Analysis of Al2O3/Water–TiO2/Chlorophyll Hybrid Nanofluids in a Photovoltaic–Thermal Solar Water Heating System

open access: yesEnergy Science &Engineering, EarlyView.
TiO2/chlorophyll bio‐hybrid nanofluid achieved the highest PVT performance, increasing thermal efficiency to 38.74% and overall efficiency to 51.35%, compared with 35.96% and 48.45% for Al2O3/water and 27.77% and 40.18% for water. The results demonstrate the potential of bio‐hybrid nanofluids for high‐efficiency solar thermal energy conversion ...
Oluwaseyi Omotayo Alabi   +2 more
wiley   +1 more source

Fault‐Specific Diagnostic Regions Based on Normalized DC Voltage and Current Indices for Photovoltaic Systems Using Routine Inverter and Environmental Data

open access: yesEnergy Science &Engineering, EarlyView.
This study proposes a fault diagnostic approach for photovoltaic systems using normalized DC voltage and current indices derived from routinely collected inverter and environmental data. The approach enables string‐ and array‐level fault diagnosis without additional measurement equipment and supports operation and maintenance decision‐making.
Woo Gyun Shin   +5 more
wiley   +1 more source

Home - About - Disclaimer - Privacy