Enhanced depth imaging optical coherence tomography of the optic nerve head improves correct diagnosis in glaucoma suspects without glaucomatous optic disc morphology. [PDF]
Ahmadi H, Kolko M, Hamann S.
europepmc +1 more source
Binder‐free laser powder bed fusion of 8YSZ with a femtosecond laser is used to map process windows linking scan strategy, heat accumulation, and grain growth. Time‐resolved thermography and simulations reveal thermal regimes that enable continuous, vitrified, and fine‐grained 8YSZ surface layers without absorptive additives and demonstrate ...
Markus Kühn +5 more
wiley +1 more source
Stereoscopic 3D Technologies for Accurate Depth Tasks: A Theoretical and Empirical Study [PDF]
In the last decade an increasing number of application fields, including medicine, geoscience and bio-chemistry, have expressed a need to visualise and interact with data that are inherently three-dimensional.
FRONER, BARBARA
core
Rapidly Solidified High‐Strength Invar 36 Prepared by Planar‐Flow Melt Spinning
The Invar 36 alloy was rapidly solidified using the planar‐flow melt‐spinning technique. Ribbon samples with thicknesses ranging from 20 to 160 mm were produced. As the grain size of the ribbon decreased to sub‐micron levels, the hardness increased by more than 2 times.
Bekir Akgül, Mehmet Kul
wiley +1 more source
Optic disc drusen (ODD) can present a confounding clinical picture because they are often difficult to differentiate from disc edema. As OCT technology has evolved, enhanced depth imaging EDI-OCT has become a valuable tool for diagnosing ODD. In spite of
John Wilkinson; Padmaja Sudhakar
core
Semi-Automated Quantification of Retinal and Choroidal Biomarkers in Retinal Vascular Diseases: Agreement of Spectral-Domain Optical Coherence Tomography with and without Enhanced Depth Imaging Mode. [PDF]
Kessler LJ +4 more
europepmc +1 more source
Gallium microalloying redirects interfacial reactions in low‐temperature Bi–Sn solders from Cu–Sn toward Cu–Ga intermetallic formation. The resulting Cu–Ga layer suppresses intermetallic growth during thermal aging, alters fracture pathways, and improves interfacial stability.
Iva Králová +6 more
wiley +1 more source
A Novel Approach to Estimate the Transition Temperature via Dynamic Nanoindentation
A new dynamic nanoindentation‐based method was developed that uses the stiffness ratio as an indicator of the elastic–plastic deformation contributions at different temperatures. The approach successfully identified transition temperatures in ferritic steel and distinguished them from continuously ductile austenitic steel.
Stefan Zeiler +4 more
wiley +1 more source
Repeatability of wide-field choroidal thickness using enhanced depth imaging optical coherence tomography [PDF]
Purpose\ud \ud Despite recent advances in choroidal imaging, the repeatability of choroidal thickness (CT) measurements beyond the macular area (central 30˚) remains unknown.
Collins, Michael +4 more
core
Near‐surface deuterium enrichment profiles for different microstructural types of TiAl after exposure at 700 °C in a heavy water‐containing environment. The deuterium levels are significantly higher than expected from natural occurrence, indicating that the heavy water dissociated during the exposure treatment and entered the specimens.
Jonathan D. H. Paul +5 more
wiley +1 more source

