Results 111 to 120 of about 2,664 (222)

The epithermal neutron irradiation station for boron neutron capture therapy (BNCT) at the FiR 1 in Otaniemi

open access: yes, 1996
The optimal neutron field for BNCT would have only neutrons of the epithermal energy range and would be free of γ-radiation. Such a field penetrates several centimeters into the tissue but does not cause damage so much as higher energy neutrons would. In
Auterinen, Iiro, Hiismaki, Pekka
core   +1 more source

The epithermal neutron beam for BNCT under construction at TAPIRO: Physics

open access: yes, 2006
A column to provide an epithermal neutron beam suitable for experimental and clinical BNCT is nearing completion at the TAPIRO reactor (ENEA Casaccia, Rome). TAPIRO is a compact, low power (5 kW), helium-cooled, fast reactor.
Nava, E.   +3 more
core  

The influence of an additional filter in epithermal neutron activation analysis

open access: yes, 1989
Additional filters of tungsten and sodium in different thicknesses have been used in the epithermal neutron activation analysis of geological samples to reduce the interferences caused by resonance neutron capture in these two elements.
Hölttä, Pekka   +4 more
core   +1 more source

Correlation of Lunar South Polar Epithermal Neutron Maps: Lunar Exploration Neutron Detector and Lunar Prospector Neutron Detector

open access: yes, 2010
The Lunar Reconnaissance Orbiter's (LRO), Lunar Exploration Neutron Detector (LEND) was developed to refine the lunar surface hydrogen (H) measurements generated by the Lunar Prospector Neutron Spectrometer.
Sagdeev, R.   +15 more
core  

Dose measurements and calculations in the epithermal neutron beam at the Brookhaven Medical Research Reactor (BMRR) [PDF]

open access: yes, 1990
The characteristics of the epithermal neutron beam at BMRR were measured, calculated, and reported. This beam has already been used for animal irradiations. We anticipate that it will be used for clinical trials.
Kalef-Ezra, J.   +6 more
core  

Coarse-Scaling Adjustment of Fine-group Neutron Spectra for Epithermal Neutron Beams in BNCT using Multiple Activation Detectors

open access: yes, 2009
In order to provide an improved and reliable neutron source description for treatment planning in boron neutron capture therapy (BNCT), a spectrum adjustment procedure named coarse-scaling adjustment has been developed and applied to the neutron spectrum
LIU Yuan-Hao   +5 more
core   +1 more source

Demonstration of Near-Epithermal Neutron Reflective Optics

open access: yes
Specular reflection of neutrons on material surfaces has been demonstrated in the energy range of 0.09-0.7 eV. The results suggest that the applicable energy range of reflective neutron optics can be extended to the near-epithermal region by using ...
Sakai, Kenji   +13 more
core  

A Technique for Reducing Interferences in Epithermal Neutron Activation Analysis

open access: yes, 1985
A new epithermal neutron activation technique is described. The technetium is based on the existence of non-overlapping resonance peaks in the neutron absorption cross-section spectra for the nuclides present in the sample to be analyzed.
Skarnemark, Gunnar,
core   +1 more source

Recent improvements in the nuclear reactor dosimetry techniques for the epithermal neutron flux measurement

open access: yes, 2017
International audienceReactor dosimetry techniques are commonly used for the characterization of neutron spectra (both shape and level) encountered in nuclear reactors.
Lyoussi, A.   +13 more
core  

Home - About - Disclaimer - Privacy