COMP Report: CPQR technical quality control guidelines for use of positron emission tomography/computed tomography in radiation treatment planning

open access: yesJournal of Applied Clinical Medical Physics, Volume 23, Issue 12, December 2022., 2022
Abstract Positron emission tomography with x‐ray computed tomography (PET/CT) is increasingly being utilized for radiation treatment planning (RTP). Accurate delivery of RT therefore depends on quality PET/CT data. This study covers quality control (QC) procedures required for PET/CT for diagnostic imaging and incremental QC required for RTP.
Ran Klein   +7 more
wiley   +1 more source

A small footprint couch‐top support device for image‐guided radiotherapy of heavy patients

open access: yesJournal of Applied Clinical Medical Physics, Volume 23, Issue 12, December 2022., 2022
Abstract Purpose Patients with body weights close to or above 400 lbs present unique challenges in radiation therapy since the weight limit of most treatment couches decreases as the couch‐top extends toward the treatment gantry. The purpose of this work was to develop a small footprint couch‐top support platform to safely perform image‐guided ...
Huixiao Chen   +5 more
wiley   +1 more source

Image quality comparisons of coil setups in 3T MRI for brain and head and neck radiotherapy simulations

open access: yesJournal of Applied Clinical Medical Physics, Volume 23, Issue 12, December 2022., 2022
Abstract Purpose MRI is increasingly used for brain and head and neck radiotherapy treatment planning due to its superior soft tissue contrast. Flexible array coils can be arranged to encompass treatment immobilization devices, which do not fit in diagnostic head/neck coils. Selecting a flexible coil arrangement to replace a diagnostic coil should rely
Evangelia Kaza   +6 more
wiley   +1 more source

Crystal structure of posnjakite formed in the first crystal water-cooling line of the ANSTO Melbourne Australian Synchrotron MX1 Double Crystal Monochromator

open access: yesActa Crystallographica Section E: Crystallographic Communications, 2020
Exceptionally large crystals of posnjakite, Cu4SO4(OH)6(H2O), formed during corrosion of a Swagelock(tm) Snubber copper gasket within the MX1 beamline at the ANSTO-Melbourne, Australian Synchrotron.
Stuart Mills   +12 more
doaj   +1 more source

Clinical commissioning of an adaptive radiotherapy platform: Results and recommendations

open access: yesJournal of Applied Clinical Medical Physics, Volume 23, Issue 12, December 2022., 2022
Abstract Online adaptive radiotherapy platforms present a unique challenge for commissioning as guidance is lacking and specialized adaptive equipment, such as deformable phantoms, are rare. We designed a novel adaptive commissioning process consisting of end‐to‐end tests using standard clinical resources.
Kelly Kisling   +5 more
wiley   +1 more source

Application value of contrast‐enhanced ultrasound in preoperative localization of microwave ablation for primary hyperparathyroidism

open access: yesJournal of Applied Clinical Medical Physics, Volume 23, Issue 12, December 2022., 2022
Abstract Background Ultrasonography (US) and 99mTechnetium‐sestamibi scintigraphy (99mTc‐MIBI) are currently first‐line imaging modalities to localize parathyroid adenomas with sensitivities of 80% and 84%, respectively. Therefore, finding other modalities to further improve the diagnostic accuracy for preoperative localization is critically needed ...
Fangyi Liu   +7 more
wiley   +1 more source

Statistical process control to monitor use of a web‐based autoplanning tool

open access: yesJournal of Applied Clinical Medical Physics, Volume 23, Issue 12, December 2022., 2022
Abstract Purpose To investigate the use of statistical process control (SPC) for quality assurance of an integrated web‐based autoplanning tool, Radiation Planning Assistant (RPA). Methods Automatically generated plans were downloaded and imported into two treatment planning systems (TPSs), RayStation and Eclipse, in which they were recalculated using ...
Hunter Mehrens   +5 more
wiley   +1 more source

Optimising Age-Replacement and Extended Non-Renewing Warranty Policies in Lifecycle Costing [PDF]

open access: yes, 2011
This paper analyses the life cycle cost of equipment protected by both base and extended warranty policies from a consumer's perspective. We assume that the equipment has two types of failure: minor and catastrophic. A minor failure can be corrected with
Longhurst, Phil, Wu, Shaomin
core   +2 more sources

Risikomanagement für medizinische Netzwerke in der Intensiv- und Notfallmedizin. Gemeinsames Positionspapier zur Norm IEC 80001-1 [Risk management for medical networks in intensive care and emergency medicine – a joint position paper on IEC 80001-1]

open access: yesGMS Medizinische Informatik, Biometrie und Epidemiologie, 2013
[english] IEC 80001-1 is an international standard and offers recommendations for a risk management process for medical information technology networks (MITs). MITs are defined as IT networks incorporating at least one medical device.
Imhoff, Michael   +6 more
doaj   +1 more source

Adjustment Factor Model of Relay Protection Equipment Failure Rate Based on Data Fitting

open access: yesZhongguo dianli, 2021
Analyzing the impact of equipment maintenance on the failure rate of relay protection equipment is helpful to the formulation of relay protection equipment maintenance plans and the realization of long-term stable and reliable operation of the power grid.
Huping YANG   +5 more
doaj   +1 more source