Results 11 to 20 of about 1,051,691 (327)
Abstract Positron emission tomography with x‐ray computed tomography (PET/CT) is increasingly being utilized for radiation treatment planning (RTP). Accurate delivery of RT therefore depends on quality PET/CT data. This study covers quality control (QC) procedures required for PET/CT for diagnostic imaging and incremental QC required for RTP.
Ran Klein+7 more
wiley +1 more source
A small footprint couch‐top support device for image‐guided radiotherapy of heavy patients
Abstract Purpose Patients with body weights close to or above 400 lbs present unique challenges in radiation therapy since the weight limit of most treatment couches decreases as the couch‐top extends toward the treatment gantry. The purpose of this work was to develop a small footprint couch‐top support platform to safely perform image‐guided ...
Huixiao Chen+5 more
wiley +1 more source
Abstract Purpose MRI is increasingly used for brain and head and neck radiotherapy treatment planning due to its superior soft tissue contrast. Flexible array coils can be arranged to encompass treatment immobilization devices, which do not fit in diagnostic head/neck coils. Selecting a flexible coil arrangement to replace a diagnostic coil should rely
Evangelia Kaza+6 more
wiley +1 more source
Exceptionally large crystals of posnjakite, Cu4SO4(OH)6(H2O), formed during corrosion of a Swagelock(tm) Snubber copper gasket within the MX1 beamline at the ANSTO-Melbourne, Australian Synchrotron.
Stuart Mills+12 more
doaj +1 more source
Clinical commissioning of an adaptive radiotherapy platform: Results and recommendations
Abstract Online adaptive radiotherapy platforms present a unique challenge for commissioning as guidance is lacking and specialized adaptive equipment, such as deformable phantoms, are rare. We designed a novel adaptive commissioning process consisting of end‐to‐end tests using standard clinical resources.
Kelly Kisling+5 more
wiley +1 more source
Abstract Background Ultrasonography (US) and 99mTechnetium‐sestamibi scintigraphy (99mTc‐MIBI) are currently first‐line imaging modalities to localize parathyroid adenomas with sensitivities of 80% and 84%, respectively. Therefore, finding other modalities to further improve the diagnostic accuracy for preoperative localization is critically needed ...
Fangyi Liu+7 more
wiley +1 more source
Statistical process control to monitor use of a web‐based autoplanning tool
Abstract Purpose To investigate the use of statistical process control (SPC) for quality assurance of an integrated web‐based autoplanning tool, Radiation Planning Assistant (RPA). Methods Automatically generated plans were downloaded and imported into two treatment planning systems (TPSs), RayStation and Eclipse, in which they were recalculated using ...
Hunter Mehrens+5 more
wiley +1 more source
Optimising Age-Replacement and Extended Non-Renewing Warranty Policies in Lifecycle Costing [PDF]
This paper analyses the life cycle cost of equipment protected by both base and extended warranty policies from a consumer's perspective. We assume that the equipment has two types of failure: minor and catastrophic. A minor failure can be corrected with
Longhurst, Phil, Wu, Shaomin
core +2 more sources
[english] IEC 80001-1 is an international standard and offers recommendations for a risk management process for medical information technology networks (MITs). MITs are defined as IT networks incorporating at least one medical device.
Imhoff, Michael+6 more
doaj +1 more source
Adjustment Factor Model of Relay Protection Equipment Failure Rate Based on Data Fitting
Analyzing the impact of equipment maintenance on the failure rate of relay protection equipment is helpful to the formulation of relay protection equipment maintenance plans and the realization of long-term stable and reliable operation of the power grid.
Huping YANG+5 more
doaj +1 more source