Results 41 to 50 of about 519,794 (275)
Highly accurate measurements of infrared systems cannot be achieved without precise radiometric calibrations. In order to correctly interpret and process infrared images and monitor the performance of infrared cameras, their radiometric calibration is ...
Xinyu Pang +5 more
doaj +1 more source
A novel broadband equivalent source reconstruction method for broadband radiators [PDF]
Traditional equivalent source reconstruction methods are only operating at a single frequency point each time. However, for wide band radiators, their computation cost of the source reconstruction increases linearly with the number of frequency points ...
Hu, Jun +7 more
core +2 more sources
A global Curie depth model utilising the equivalent source magnetic dipole method [PDF]
An updated global Curie depth model by employing the equivalent source dipole method to fit the lithospheric magnetic field model LCS-1 from spherical harmonic degree 16 to ...
matthew.gard@adelaide.edu.au, M (via Mendeley Data)
core +1 more source
Sound Scattering and Its Reduction by a Janus Sphere Type [PDF]
Copyright © 2014 Delyia Kim et al. This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.Sound
Kim, D, Miloh, T, AVITAL, E
core +1 more source
The equivalent source is a simple and effective method to level and manipulate magnetic data. However, large misfits between the predicted and synthetic data for different components of the magnetic field are observed when a single layer equivalent ...
Duan Li +5 more
doaj +1 more source
ABSTRACT A lethal round‐cell malignancy with an MN1::ZNF341 fusion has recently been reported in three infants. Here, we describe four further tumors, three in newborns (including monozygotic twins), and one in an adolescent. Detailed clinical, radiological, and histopathological data differentiate these tumors from their main mimics, neuroblastoma and
Thomas R. W. Oliver +25 more
wiley +1 more source
Dictionary-based Equivalent Source Method for Near-Field Acoustic Holography [PDF]
In this paper, we propose a modification of the standard Equivalent Source Method (ESM) for Near-Field Acoustic Holography (NAH). As in EMS, we aim at modeling the acoustic pressure radiated from a vibrating object, and its surface velocity, as the joint
Antonacci, Fabio +7 more
core +1 more source
The time-domain inverse technique based on the time-domain rotating equivalent source method has been proposed to localize and quantify rotating sound sources.
Xiaozheng Zhang +5 more
doaj +1 more source
Natural Killer Cells in Paediatric Soft Tissue Sarcomas: A Systematic Review
ABSTRACT Paediatric soft tissue sarcomas (pSTS) are a rare and heterogeneous group of malignant tumours arising in tissues of mesenchymal origin. The role of natural killer (NK) cells in pSTS remains poorly understood, with evidence fragmented across small preclinical studies and early‐phase clinical trials.
Raya Dean +7 more
wiley +1 more source
Improved-Accuracy Source Reconstructionon Arbitrary 3-D Surfaces [PDF]
This paper presents a novel formulation of the source reconstruction problem on arbitrary three-dimensional (3-D) surfaces based on integral equations. Rigorous boundary integral field identities are employed to enforce that the two unknown currents are ...
Vecchi, Giuseppe +1 more
core +1 more source

