Results 241 to 250 of about 1,133,582 (293)

An Equivalent Circuit Model for the Wire-to-Surface Junction Based on Method of Moments

open access: yes2016 IEEE/ACES International Conference on Wireless Information Technology and Systems (ICWITS) and Applied Computational Electromagnetics (ACES), 2016
A modified wire-to-surface junction basis function is proposed in this paper in order to facilitate the extraction of an equivalent circuit model for the wire-to-surface junction. The circuit extraction is based on an MPIE formulation. The extracted circuit model has been validated by the traditional EFIE formulation.
Jun Fan, Yansheng Wang, Nevin Altunyurt
exaly   +3 more sources

Multi-Wire Microstrip Interconnections: A Systematic Analysis for the Extraction of an Equivalent Circuit

51st ARFTG Conference Digest, 1998
A systematic analysis of the multi-wire microstrip interconnection is proposed in this work. A family of structures has been analyzed by considering single-, double- and triple-wire interconnections and by varying the typical geometrical parameters.
Luca Roselli   +2 more
exaly   +4 more sources

A Simplified 2-D Equivalent Model for Magnetic Wire Array [PDF]

open access: yesIEEE Transactions on Magnetics, 2022
Demagnetization factor and corresponding apparent permeability for multi-wire arrays using the 3D finite element method are calculated in this paper. The effect of distance between magnetic wires on the demagnetization factor and apparent magnetic permeability is studied for various values of relative magnetic permeability. The simulations are compared
Mehran Mirzaei, Pavel Ripka, Vaclav Grim
openaire   +2 more sources

Equivalent Circuit With Frequency-Independent Lumped Elements for Coated Wire Antennas

IEEE Transactions on Antennas and Propagation, 2012
A 7-element lumped-parameter equivalent circuit is derived for wire antennas coated with a thin dielectric and/or magnetic material. The derivation is based on a method for transforming any coating to an equivalent magnetic coating on a wire with a different radius.
Todd H. Hubing, Donglin Su
exaly   +2 more sources

Analytical Methods for Estimating Equivalent Thermal Conductivity in Impregnated Electrical Windings Formed Using Litz Wire

open access: yes, 2017
This paper discusses two analytical methods used in estimating the equivalent thermal conductivity of impregnated electrical windings constructed with Litz wire.
Rafal Wrobel, Sabrina Ayat
exaly   +6 more sources

Wired Equivalent Privacy (WEP)

2009 International Conference on Future Computer and Communication, 2009
There are some demonstrable reasons for customers who like use from wireless technology and this is clear because there are various benefits for using wireless technology. The contrast between wireless usage and security techniques growing, show that the security is not adequate enough for this data growing.
Arash Habibi Lashkari   +2 more
openaire   +1 more source

Wired equivalent privacy reinvestigated

Journal of Discrete Mathematical Sciences and Cryptography, 2010
Abstract Security is a strong requirement for effective deployment of business wireless communication applications. Therefore, many proposals dealt with security holes in Wired Equivalent Privacy protocol (WEP). In this paper, we analyze WEP security holes and we propose an improvement over WEP which achieves its security goals.
Amar Kumar Mohapatra, Nupur Prakash
openaire   +1 more source

An equivalent circuit for the double bonding wire interconnection

1999 IEEE MTT-S International Microwave Symposium Digest (Cat. No.99CH36282), 2003
This work proposes a quasi-static model for the double bonding wire interconnection. The wires have been assumed to be parallel, while their curvature has been described with an arc of circle. The model is based on the representation of the structure by means of four sections of a uniform, homogeneous transmission line.
ALIMENTI, Federico   +3 more
openaire   +2 more sources

An Equivalent Complex Permeability Model for Litz-Wire Windings

IEEE Transactions on Industry Applications, 2005
Previous methods for calculating power loss in litz-wire windings usually assume very fine strands such that the diameter of strands is much smaller than skin depth. In this paper, we present a method for calculating proximity-effect loss in litz-wire windings.
null Xi Nan, C.R. Sullivan
openaire   +1 more source

On the equivalent circuit approximation of magnetoimpedance in amorphous wires

Materials Letters, 1998
Abstract The magnetoimpedance response of CoFeBSi wires was measured at frequencies equal, below and above the relaxation frequency. We show that the behavior of the real and imaginary parts of inductance, as a function of the current amplitude is clearly consistent with modeling of the wire response by means of a parallel RL equivalent circuit.
K.L. GarcĂ­a, R. Valenzuela
openaire   +1 more source

Home - About - Disclaimer - Privacy