Results 81 to 90 of about 109,640 (243)
This study presents a high‐performance moisture‐induced power generator (MPG) that integrates a LiCl‐containing hydrogel, an aluminum sheet, and NaV3O₈ nanobelts. The device sustains stable moisture and ion concentration gradients while preventing charge accumulation, resulting in record‐high performance with an open‐circuit voltage of 1.64 V, a short ...
Hyerim Baek +5 more
wiley +1 more source
Eriochrome Black T inhibits endothelial cell growth through S-phase blockade.
We used human umbilical vein endothelial cells (HUVEC) cultures to investigate in vitro the antiproliferative effects of suramin and of its analogue, Eriochrome Black T.
Atassi, Ghanem +3 more
core
A wearable electrochemical biosensor integrated into a smart mouthguard enables the non‐invasive detection of salivary MMP‐8 for early monitoring of periodontal inflammation. Featuring a molecularly imprinted polymer‐based sensing layer, the platform offers high cytokine selectivity and impedance‐driven sensitivity. Combining wireless connectivity with
Sangheon Jeon +10 more
wiley +1 more source
Schematic illustration of biosensor technology for detection of ACV. ABSTRACT Objective This study investigates the innovative application of nanomaterial‐based micro‐devices aimed at enhancing the diagnosis and management of acyclovir (ACV) for herpes virus infections, specifically those caused by HSV‐1, HSV‐2, CMV, and VZV.
Mohammad Darvishi +5 more
wiley +1 more source
A polymerized film of Eriochrome black T (EBT) was prepared on the surface of carbon paste electrode (CPE) in alkaline solution by cyclic voltammetry. The poly (EBT) film-coated CPE exhibited excellent electrocatalytic activity towards the oxidation of ...
Ongera Gilbert +3 more
doaj +1 more source
Eriochrome black T as a dye for agarose gel electrophoresis.
We found that it is possible to use eriochrome black T as a dye for agarose gel electrophoresis of DNA. The presence of the dye does not change the migration rate of DNA and does not influence the electrophoretical picture.
M, Obuchowski, G, Wegrzyn
openaire +1 more source
Anadolu Üniversitesi ve Bilecik Şeyh Edebali Üniversitesi tarafından ortak yürütülen program.Adsorbent olarak Rhizopus arrhizus, aktif karbon ve amberlyst kullanılarak Eriochrome Black T’nin sulu çözeltiden giderimi çalışılmıştır.
Çetinbaş, Kader
core
A spectrophotometric method based on the formation of ion-pair complex between haloperidol and eriochrome black T (EBT) at pH 1.85 has been described. The formed complex was extracted quantitatively into chloroform and measured at 510 nm.
Nafisur Rahman +2 more
doaj +1 more source
The removal of synthetic dyes from wastewater remains a major environmental challenge due to their toxicity, persistence, and resistance to traditional treatment methods.
Abosede Adejoke Badeji +4 more
doaj +1 more source
エリオクロムブラックT,ムレキシド,NNなどのように錯滴定における金属指示薬によるマグネシウムの比色定量法は種々試みられているが,それら錯体の抽出は報告されていない.著者らはエリオクロムブラックTとマグネシウムとの錯体をn-アミルアルコールに抽出後,677.5mμにおける吸光度の減少から,マグネシウムを定量した.従来の水溶液比色法と比べて数倍感度がよく,またn-アミルアルコール中では,EBT自身,マグネシウム-EBT錯体ともに安定であることが利点である.0.08ppm以下の微量のマグネシウムの定量が可能である.
NISHIMURA, Masakichi, NAKAYA, Syu
openaire +2 more sources

