Results 41 to 50 of about 495,403 (268)
Design and Analysis of a Bearing-Integrated Rotary Transformer
In this paper, a bearing- and transformer-integrated electric excitation synchronous motor excitation system (bearing-integrated rotary transformer) is proposed to support the motor rotor and energy transmission of excitation systems.
Xiaoou Fan +3 more
doaj +1 more source
Simulation research on excitation system of multi-electrode blood flow meter
In order to monitor human blood flow rate and flow velocity distribution, a blood flow meter based on multi-electrode electromagnetic measurement has been proposed to measure the flow velocity of the arteriovenous blood by obtaining the induced voltage ...
Yuyang ZHAO +3 more
doaj +1 more source
ABSTRACT Introduction Adolescent siblings of children with cancer are at elevated risk for psychosocial problems. Unfortunately, various barriers such as limited family time and resources, conflicting schedules, and psychosocial staffing constraints at cancer centers hinder sibling access to support.
Christina M. Amaro +10 more
wiley +1 more source
Modification of the implementation of the underexcitation limiter within the generator excitation system of Unit B1 at TPP "Nikola Tesla B" [PDF]
This paper investigates a grid outage event at TPP "Nikola Tesla B" Unit B1 and analyzes the excitation system's response. Based on this analysis, modifications were made to the underexcitation limiter within the excitation system.
Klasnić Ilija +5 more
doaj +1 more source
ABSTRACT Pediatric gastroenteropancreatic neuroendocrine neoplasms (GEP‐NENs) are extremely rare and clinically heterogeneous. Management has largely been extrapolated from adult practice. This European Standard Clinical Practice Guideline (ESCP), developed by the EXPeRT network in collaboration with adult NEN experts, provides (adult) evidence ...
Michaela Kuhlen +23 more
wiley +1 more source
Frequency-Diverse Metasurface Antenna With Hybrid Bunching Methods for Coincidence Imaging
A frequency-diverse metasurface antenna with hybrid bunching methods for coincidence imaging is proposed in this paper. The hybrid frequency-diverse bunching metasurface antenna contains an excitation system, a frequency-diverse metasurface and a double ...
Mengran Zhao +5 more
doaj +1 more source
Coded Excitation for Pulse-Echo Systems
Pulse compression has been used for decades in radar, sonar, medical, and industrial ultrasound. It consists in transmitting a modulated or coded excitation, which is then cross-correlated with the received signal such that received echoes are time compressed, thereby increasing their intensity and hence the system resolution and signal-to-noise ratio (
Julio Isla, Frederic Cegla
openaire +4 more sources
ABSTRACT Introduction Adult‐onset Still's disease (AOSD) complicated by macrophage activation syndrome (MAS) carries substantial mortality. The role of therapeutic plasma exchange (TPE) remains uncertain. Methods We retrospectively analyzed patients with AOSD‐MAS treated with TPE at a single‐center.
Masataka Ueda +15 more
wiley +1 more source
Modelling of patient-specific Purkinje activation based on measured ECGs
The Purkinje system is part of the fast-conducting ventricular excitation system. The anatomy of the Purkinje system varies from person to person and imposes a unique excitation pattern on the ventricular myocardium, which defines the morphology of the ...
Kahlmann Willi +4 more
doaj +1 more source
Revealing the structure of land plant photosystem II: the journey from negative‐stain EM to cryo‐EM
Advances in cryo‐EM have revealed the detailed structure of Photosystem II, a key protein complex driving photosynthesis. This review traces the journey from early low‐resolution images to high‐resolution models, highlighting how these discoveries deepen our understanding of light harvesting and energy conversion in plants.
Roman Kouřil
wiley +1 more source

